Congratulations: You have purchased a product of superior performance and design, which will give the best service when
properly installed, operated and maintained. These coolers can be used as convenient, roll-around spot coolers.
This guide will provide you with information needed to assemble the unit for roll-around spot-cooling. It also contains information
on how to safely operate, inspect, maintain and troubleshoot your evaporative air cooler.
The first section, Assembly, contains instructions to prepare your cooler for roll-around portable service. The second section,
Maintenance, contains operational and maintenance instructions to aid in keeping your unit in good working order, while
Troubleshooting includes information to help diagnose and repair commonly encountered problems.
WARNING
-
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
• Read all instructions carefully before installation.
• This cooler must be connected to 120 Volt AC, 60 Hz (cycle)
power only. NOTE: Improper voltage will void the pump and/
or motor warranties and may cause serious personal injury
or property damage.
• This cooler must be plugged into a GFCI protected
receptacle, which has been properly installed in accordance
with all local and national codes. If you are not sure that
the receptacle is GFCI protected, consult with a qualified
electrician.
• This cooler is equipped with a power cord having an
equipment grounding conductor and grounding plug. Do
not attempt to defeat this safety device by removing the
grounding pin.
• Do NOT step on or roll over power cord with heavy or sharp
objects. Do not operate if the plug or cord is damaged in any
way. If the unit is damaged or malfunctions, do not continue
to operate it.
• Remove the plug from the electrical receptacle by pulling on
the plug and not the cord.
• Always disconnect electrical power to unit before attempting
to work on or service your cooler.
• Do NOT operate near open containers of flammable liquids or
gases.
• Do NOT operate this blower (fan motor) with any solid-state
speed control device.
• Do NOT operate this unit with pad frame(s) and/or air outlet
grille removed, this may cause the fan motor to overload and
damage the motor.
• Never wash your cooler cabinet with garden hose, water
may harm motor and pump.
NOTE:
• Do NOT use indoors on carpet or wood floor. Unit may leak
water and could damage flooring or create a slip hazard.
• Do NOT locate or operate cooler near exhaust or vent pipes
as odors or fumes may be drawn into unit.
• Your warranty does NOT cover shipping damage. Report all
shipping damage at once to store making the delivery.
• For future reference, record the model and serial number,
date and place of purchase of your evaporative cooler here:
THE USE OF ANODE DEVICES, CHEMICAL ADDITIVES, OR
COOLER CLEANER TREATMENTS IN THIS COOLER WILL
VOID THE WARRANTY.
Model #
Serial #
Date of Purchase:
Place of Purchase:
01-999-2626 Rev. A 11/20 MB8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Master Blaster MB8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PMI Master Blaster MB8

  • Page 1 Owner’s Guide Use and Care Manual Model: MB8 Customer Service 1-800-325-6952 • Safety • Operation • Installation • Maintenance • Start-up • Troubleshooting Congratulations: You have purchased a product of superior performance and design, which will give the best service when properly installed, operated and maintained.
  • Page 2 INTRODUCTION Install float valve and hose adapter Attach the float valve to the cabinet as shown below. Locate a knock- Your evaporative air cooler was thoroughly tested and inspected out in the bottom of any of the four corner posts. The garden hose before leaving the factory.
  • Page 3 Cabinet Inspection Checklist CAUTION: After initial start-up and during periodic inspections, check for and/ This cooler is designed for connection to 120 volt AC, 60 Hz or observe the following: Refer to the Troubleshooting Chart on (cycle) power only. NOTE: Improper voltage will void the pump page 6 if necessary.
  • Page 4 Cleaning Water Pump & Hose CAUTION: Disconnect all electrical power to the cooler by removing plug from receptacle before attempting CAUTION: Disconnect all electrical power to the cooler to install, open, or service your cooler. before attempting to install, open, or service your cooler. Even while routinely inspecting or servicing the inside, the cooler CAUTION: Do not allow pump to fall over and become...
  • Page 5 Pump Motor Bearings The pump motor does not require lubrication. Changing Cooler Pads Scale may build up on outside of the Rigid Pad, which will restrict the airflow. The Rigid Pad should be removed and replaced if scale cannot be removed using the methods described below. Failure to do so may result in premature failure of components.
  • Page 6 TROUBLESHOOTING GUIDE: Should an obvious problem occur with your cooler consult the following table. If you cannot correct the problem, or if it persists, contact qualified service personnel. PROBLEM / SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Water draining from unit Float valve out of adjustment Adjust float to 2-1/2"...
  • Page 7 ITEM REPLACEMENT PART CABINET ---- 05-003-0238 BLOWER ASSEMBLY COMPLETE MOTOR ONLY 05-007-0133 BLOWER WHEEL 05-003-0093 PAD FRAME ASSEMBLY COMPLETE 05-002-0447 RIGID MEDIA (SET) 05-002-0448 GRILLE 05-001-0173 SWITCH BOX ASSEMBLY 05-007-0214 SWITCH (PUMP) 05-007-0147 SWITCH (FAN) 05-007-0148 SWITCH COVER 05-007-0215 POWER SUPPLY CORD 05-007-0186 CASTER (COMPLETE SET OF 4) 05-001-0152...
  • Page 8 Partes de reemplazo: ATodos las partes de reemplazo de PMI cuentan con una garantía de 90 días desde la fecha de su compra (o el balance de la garantía original lo que sea más). Esta es la única garantía extendida por PMI al consumidor que compra enfriadores por evaporación. PMI desconoce todas otras garantías, expresadas, que surjan por la operación de la ley, excepto que garantías implicadas de comerciabilidad o conveniencia para un propósito particular son limitadas a la duración del limitado...

Table of Contents