DIGITAL SYSTEMS, PROGRAMMING, OPERATION AND ERROR MESSAGES
START UP
When your hot tub is first powered up, it will
automatically heat and maintain 100°F / 37.5°C
until you change the set temperature.
TEMPERATURE ADJUSTMENT
(60°F-104°F) / (16°C-40°C)
Press the
pad to display the temperature
previously set. This set temperature is flashed on the
display. In a few seconds, the numbers will stop
flashing, and the display will show the actual
temperature. Pressing the pad a second time will
cause the set temperature to increase or decrease
depending on what direction was last chosen. Each
press to follow will change the set temperature in
the same direction. If the opposite direction is
desired release the pad and let the display revert to
the actual water temperature. Press the pad to
display the set temperature, and again to make the
temperature change in the desired direction. Actual
water temperature will reappear on the display after
changing the temperature setting.
MASSAGE
Press the
pad to activate the pump's low speed,
again for the pump's high speed, and once more to
turn off the pump. The pump's low speed turns off
after 1 hour. The pump's high speed turns off after
15 minutes.

500 Series Digital 2000 System

- 11 -
TURBO (OPTIONAL)
Press the
pad to turn the blower on and off. If
left running, the turbo automatically turns off after
15 minutes.
LIGHT
Press the
pad to turn the hot tub light on and
off. The light will automatically turn off after 2 hours
of use.
FILTER CYCLE PROGRAMMING
Due to the energy efficiency of the Hush Pump™,
your hot tub is set to automatically filter itself 24
hours a day. Although, there are other durations, it is
not necessary to change this setting. Filter duration
is programmable at the top-side panel. Press the
pad, then the
pad within 3 seconds and "FC"
will be displayed on the panel. ("FC" is the default
filter time and indicates a 12 hour cycle.) Continue
pressing the
pad to cycle through the rest of
the filter time options: "F2" - 2 hours, "F4" - 4
hours, "F6" - 6 hours, "F8" - 8 hours, "F0" - 10
hours, and FC for 12 hours. Press
select number of cycles per day. Press
- one cycle or "C2" – two cycles. Press
exit programming mode. Note: If your hot tub is not
equipped with Hush pump™ then the factory default
setting is, F2-C2. Use the instructions above to
change if desired. The higher the bather load or
use frequency, the higher the filter setting needed.