is not fitted with a condensate disposal system. The air curtain should only be
configured to operate in COOL mode if it is fitted with a condensate disposal system.
Adjust the airstream vanes at each end of the discharge grille as shown in the diagram:
Switch off the electrical power to the Air Curtain and the Mitsubishi Electric Outdoor
Unit. Carefully slide the Interface PCB back into place and re-plug the Filter Indication
connection into CN105 if removed earlier. Ensure cables are not trapped inside and refit
the retaining screw.

Filter Dirty Indicator

The air curtain is fitted with a Filter Dirty Indicator. It is located inside
the unit above the left-hand sliding access panel and signals when the
air curtain inlet grille/filters should be vacuum cleaned or the air curtain
requires servicing.
NB.The filter dirty interval feature on the Mitsubishi Electric remote
controller is not available.
T9901105-1-1 UK
Adjustable
Airstream Vanes
Angled
airstreams
project into
un-protected
gap at end of
air curtain
Main
airstream
Standard outlet
grille projects main
airstream straight
down
Adjustable
Airstream Vanes
at each end of the
standard outlet
grille
Angled airstreams
project into
un-protected gap at
end of air curtain
Page 31 of 42