90
STEP 1
Maintenance and Care for the Equipment Owner
Before performing equipment maintenance
carefully consider the following:
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK AND
CUT HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
1. Turn off gas supply first, then all electrical power to your
unit and install lock- -out tag before servicing or per-
forming maintenance.
2. When
removing
access
maintenance functions inside your unit, be aware of
sharp sheet metal parts and screws. Although special care
is taken to reduce sharp edges to a minimum, be
extremely careful when handling parts or reaching into
the unit. Wear safety glasses, gloves, and appropriate
protective clothing.
Air Filters
The air filter(s) should be checked
changed or cleaned whenever it becomes dirty. Dirty filters
produce excessive stress on the blower motor and can cause the
motor to overheat and shut down.
This unit must have air filters in place before it can be operated.
These filters can be located in one of at least two places. In many
applications, the installer will provide return air filter grilles
mounted on the wall or ceiling of the conditioned structure. In the
instance of filter grilles, the filters can simply be removed from the
grille and replaced.
The other typical application is an accessory filter rack installed
inside the unit itself. The following information is given to assist in
changing filters used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory
installed option. The same filter kit is included with the accessory
economizers and factory installed economizers.
Table 1 – Replacement Filter Sizes
Unit Size
24-040/060
30-040/060
36-060/090
1 each 24 x 14 x 1 (610 x 356 x 25 mm),
42-060/090
24 x 16 x 1 (610 x 406 x 25 mm)
1 each 24 x 14 x 1 (610 x 356 x 25 mm),
48-090/115/130
24 x 16 x 1 (610 x 406 x 25 mm)
1 each 24 x 16 x 1 (610 x 406 x 25 mm),
60-090/115/130*
24 x 18 x 1 (610 x 457 x 25 mm)
*Units with bent indoor coil.
Fig. 7 - - To Shut- -off Unit Electric Cooling
yourself, please
panels
or
performing
every 3 or 4 weeks and
Filter Size
2 each 20 x 12 x 1
(508 x 305 x 25 mm)
2 each 20 x 12 x 1
(508 x 305 x 25 mm)
2 each 20 x 12 x 1
(508 x 305 x 25 mm)
STEP 2
To replace or inspect filters in accessory filter rack (See Fig. 2):
1. Remove the filter access panel using a 5/16- -in. nut driver.
2. Remove the filter(s) by pulling it out of the unit. If the
filter(s) is dirty, clean or replace with a new one.
When installing the new filter(s), note the direction of the airflow
arrows on the filter frame which should be pointing at the indoor
coil.
3. Reinstall filter access panel ensuring opening is air and
water tight.
If you have difficulty locating your air filter(s) or have questions
concerning proper filter maintenance, contact your dealer for
instructions. When replacing filters, always use the same size and
type of filter that was supplied originally by the installer. See Table
1 for filter sizes supplied with accessory filter rack.
Replacing or inspecting filters in units with econom-
izers
Small Chassis (See Fig. 8)
1. Remove return air duct cover at rear of unit using a 5/16- -in.
nut driver.
2. Remove the filter(s) by pulling it out and through the unit
duct opening. If filter is dirty, replace both filters with new
ones.
When installing the new filters, note the direction of the airflow
arrows on the filter frame, which should be pointing at the indoor
coil.
3. Reinstall duct cover ensuring opening is air and watertight.
Large Chassis (See Fig. 9)
1. Remove filter access door using a 5/16- -in. nut driver.
2. Remove the filter(s) by pulling it out and through the unit
filter access door. If filter is dirty, replace both filters with
new ones.
Units with bent indoor coils, install 24 x 18 x 1 (610 x 457 x 25
mm) filter first and then install 24 x 16 x 1 (610 x 406 x 25) filter.
When installing the new filters, note the direction of the airflow
arrows on the filter frame, which should be pointing at the indoor
coil.
3. Reinstall filter access door ensuring opening is air and water
tight.
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in
damage.
Never operate your unit without filters in place. An
accumulation of dust and lint on internal parts of your unit
can cause loss of efficiency and blower motor and/or
compressor damage.
7
MAIN
ON
OFF
STEP 3
A07797
property