Pinnacle Climate Technologies Master MH-45-KFA User's Manual & Operating Instructions

Pinnacle Climate Technologies Master MH-45-KFA User's Manual & Operating Instructions

Kerosene forced air heater
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

MH-45-KFA / MH-80T-KFA / MH-140T-KFA / MH-190T-KFA / MH-215T-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.
DANGER
to comply with the instructions and warnings provided with this heater. Failure to comply
can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only
persons who can follow and understand these instructions should operate or service this
heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle
Climate Technologies at 800-641-6996.
DANGER
WELL-VENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY
HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER
CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater that
uses air (Oxygen) from within the area in which it is used. Failure to provide adequate
combustion and ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily
injury or death. Refer to "Ventilation" on Page 6.
FACTORY ID: 500
MODEL NUMBERS:
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUT ADEQUATE VENTILATION. THIS HEATER IS
SUITABLE FOR OUTDOOR USE, AND INDOOR USE ONLY IN
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
KEROSENE FORCED AIR
HEATER
User's Manual &
Operating Instructions
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
© 2020 Pinnacle Climate Technologies, Inc.
MAKL-424

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Master MH-45-KFA and is the answer not in the manual?

Questions and answers

Summary of Contents for Pinnacle Climate Technologies Master MH-45-KFA

  • Page 1 Refer to “Ventilation” on Page 6. FACTORY ID: 500 Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com © 2020 Pinnacle Climate Technologies, Inc. MAKL-424...
  • Page 2: Table Of Contents

    REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139. Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your KFA Heater. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 3: Safety Information

    100,000 Btu/Hr (29 kW) NOT TOUCH. KEEP CHILDREN, ANIMALS, heater rating. Refer to “Ventilation” on page 6 for CLOTHING AND COMBUSTIBLES AWAY further instructions. FROM HEATER. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 4: What's In The Box

    Axle Wheel Support Frame Axle Supports - Remove the heater and all packaging materials Note: Save the box and packaging materials from the shipping carton for future storage. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 5: Specifications

    7. Check all parts to ensure they are secure before Spacer Figure 1 operating the heater. 2. Attach the axle supports by inserting them into the button spring clips at the front of the bottom support frame. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 6: Operation

    - NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 7 “LO”. - When the temperature is more that 99 ºF the display says “HI”. - Between 0 °F and 99 °F the display shows actual temperature. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 8: Maintenance

    The wire should be lying on the bottom shell inside Lint Filter End Filter the heater with the plastic end placed under the motor support/motor and away from fan blade. Figure 3 © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 9 It may be necessary to soak the nozzle in K-1 kerosene to loosen any dirt particles. Nozzle Nozzle Face Photocell Wire Burner Head Figure 6 Figure 5 © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 10: Wiring Diagrams

    WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAMS 45-KFA 80T - 215T-KFA 80T-KFA 140T-KFA / 175T-KFA / 190T-KFA (80T-KFA) (140T-KFA) (175T-KFA / 190T-KFA / 215T-KFA) Models 140T/175T/190T/215T-KFA have a digital display. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 11: Troubleshooting Guide

    3. Check / replace the fuse. 4. Improper electrical connection 4. Inspect all electrical connections between temperature limit sensor (see wiring diagrams on page 10). and circuit board. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 33** 39** 34** 36** 35** 41** 37** 41** * 45-KFA - 80T-KFA Only ** 140T-KFA - 215T-KFA Only © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 13: Parts List

    Motor Supporter 70-020-0600 70-020-0600 70-020-0610 70-020-0610 70-020-0610 Axle Frame – – 70-041-0735 70-041-0735 70-041-0735 Safety Guard (not pictured) – – 70-065-1005 70-065-1005 70-065-1005 TIP: To order parts call 800-641-6996. © 2020 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 14: Limited Warranty

    LIMITED WARRANTY (5-YEAR MOTOR WARRANTY) Pinnacle Climate Technologies, Inc. warrants this heater to If Pinnacle Climate Technologies, Inc. finds the item to the original retail purchaser only, to be free from defects in be in normal operating condition, or not defective the item material and workmanship for a period of one (1) year from will be returned freight collect.
  • Page 15 Si necesita información sobre el calentador, como un manual de operación, etiquetas, etc. comuníquese con Pinnacle Climate Technologies al 800-641-6996. PELIGRO NO DEBE USARSE EN ÁREAS HABITABLES RESIDENCIALES NI EN ESPACIOS CERRADOS CON VENTILACIÓN INADECUADA.
  • Page 16 AUTORIDADES QUE TENGAN JURISDICCIÓN Y LA NORMA CSA B139. Busque este símbolo en el manual para encontrar consejos útiles sobre cómo armar, usar y limpiar su calentador KFA. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 17: Información De Seguridad

    Consulte “Ventilación” en la página 6 PRECAUCIÓN CALIENTE MIENTRAS ESTÉ EN para obtener más instrucciones. FUNCIONAMIENTO. NO LO TOQUE. MANTENGA A NIÑOS, ANIMALES, ROPA Y COMBUSTIBLES LEJOS DEL CALENTADOR. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 18: Qué Hay En La Caja

    - Retire el calentador y los materiales de empaque de Nota: Guarde la caja y los materiales de empaque la caja de envío para cuando guarde la unidad posteriormente. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 19: Especificaciones

    7. Antes de operar el calentador, verifique todas sujetadores de resorte de botón al frente del las piezas para asegurarse de que están bastidor de soporte inferior. seguras. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 20: Funcionamiento

    - NUNCA utilice queroseno que haya estado almacenado de una temporada a la siguiente. El queroseno se deteriora con el tiempo. EL QUEROSENO VIEJO NO SE QUEMARÁ ADECUADAMENTE EN ESTE CALENTADOR. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 21 - Cuando la temperatura es superior a 99 ºF (37 ºC) la pantalla mostrará “HI” (Alta). - Entre 0 °F (-18º C) y 99 °F (37 ºC) la pantalla mostrará la temperatura real. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 22: Mantenimiento

    Filtro de pelusa Filtro del extremo extremo de plástico colocado debajo del soporte del Figura 3 motor/motor y alejado del aspa del ventilador. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 23 K-1 para que se aflojen las partículas de suciedad. Boquilla Cara de la boquilla Cable de la fotocélula Cabeza del quemador Figura 6 Figura 5 © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 24: Diagramas Eléctricos

    8A/125AVC NEGRO ENCHUFE DE ALIMENTACIÓN NEGRO CA 120V AMARILLO BLANCO NOTA: 60 HZ Los modelos 140T/175T/ 190T/215T-KFA tienen una VERDE pantalla digital BLANCO TIERRA © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 25: Guía Para La Solución De Problemas

    Mala conexión eléctrica entre el sensor Inspeccione todas las conexiones de límite de temperatura y la placa eléctricas (consulte los diagramas de circuitos. eléctricos en la página 10). © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 26: Vista Detallada

    ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VISTA DETALLADA 33** 39** 34** 36** 35** 41** 37** 41** * Sólo 45-KFA - 80T-KFA ** Sólo 140T-KFA - 215T-KFA © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 27: Lista De Piezas

    Bastidor del eje – – 70-041-0735 70-041-0735 70-041-0735 Guardia de seguridad – – 70-065-1005 70-065-1005 70-065-1005 (no se muestra) CONSEJO: Para pedir piezas llame al (800)-641-6996. © 2020, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 28: Garantía Limitada

    DE ALIMENTACIÓN GARANTÍA LIMITADA (GARANTÍA LIMITADA DEL MOTOR DE 5 AÑOS) Pinnacle Climate Technologies, Inc. garantiza este Si Pinnacle Climate Technologies, Inc. descubre que el calentador únicamente al comprador minorista original, artículo está en condiciones normales de funcionamiento o como libre de defectos en materiales y mano de obra que no está...

Table of Contents