Download Print this page
Amana AEP222VA Product Dimensions

Amana AEP222VA Product Dimensions

Amana 20" freestanding electric range
Hide thumbs Also See for AEP222VA:

Advertisement

PRODUCT MODEL NUMBERS
AEP222VA
AEP200VA
Electrical Requirements: If codes permit and a
separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path
is adequate and wire gauge is in accordance with local
codes.
Range Rating*
120/240 Volts
120/208 Volts
8.0 - 16.5 KW
6.0 - 12.5 KW
16.6 - 22.5 KW 12.6 - 18.5 KW
*The NEC calculated load is less than the total connected
load listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated
cord with kit. For 50-amp rated cord kits, use kits that
specify use with a nominal 1 " (34.9 mm) diameter
connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable.
The model/serial rating plate is located under the left front
burner bowl.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for:
25" (63.5 cm) countertop depth
24" (61.0 cm) base cabinet depth
36" (91.4 cm) countertop height
IMPORTANT: If installing a range hood or microwave
hood combination above the range, follow the range hood
or microwave hood combination installation instructions
for dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or
metal cabinet is covered by not less than
flame retardant millboard covered with not less than No.
28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood
or metal cabinet.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is
to be provided, the risk can be reduced by installing a
range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinets.
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
20" (50.8 cm) Freestanding Electric Range
PRODUCT DIMENSIONS
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
Amps
40 or 50**
50
" (0.64 cm)
A
B
A. 36" (91.5 cm)
B. 19½" (49.5 cm)
C. 24½" (62.2 cm)
D. 42" (106.7 cm)
D
A
E
G
A. 18" (45.7 cm) min. clearance
upper side cabinet to
countertop
B. 13" (33.0 cm) max. upper
cabinet depth
C. 20" (50.8 cm) min. cabinet
opening width
D. 20 " (51.1 cm) opening width
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
D
C
B
F
C
G
H
E. 5" (12.7 cm) min. countertop
space to side wall or other
combustible material
F. For minimum clearance to top
of cooktop, see NOTE.
G. Wall receptacle - 8" (20.3 cm)
from either cabinet,
H. 5½" (14.0 cm) max. from floor.
Locate 120/240-volt
receptacle in shaded area.
Ref. W10175654B
12/20/10