System > Configuration
Access the Configuration page from the System page .
IMPORTANT NOTE - Alterations may stop your system from working - please contact BBV before changing.
Function
Logging Level
Distributed Enable
Split 1
Split 2
Split 3
Mapped Addressing
Serial Alarm Baudrate
Serial GUI baudrate
New password
Retype password
Enable dome menu access code
Please note: Both the Serial alarm interface and the GUI Interface require extra hardware - please refer to BBV.
Default
20
0
512
1023
1024
0
9600
9600
1234
Description
Includes more or less in logs.
Allows larger matrices to be constructed. For sub
512, leave at default values.
To enable camera address remapping, set to 1234.
Alarm input serial
GUI Interface
Create a new custom system password
Retype your new system password to confirm
To enable the dome menu access code, you will
need to enter '1234' in the configuration field
then restart the system. Once restarted, the fields
on the camera page will allow configuration to your
camera address mapping preferences.
Create your own specific code to restrict dome
menu access (rather than the default '1234').