Counterweight garage door automatic operator

Advertisement

3. Safety reverse force adjustment.
4. Photo beam setting
5. Auto-close setting.
Press and hold "SET" button for 3 seconds until the LED
flashes "1" Press "UP" or "DOWN" button until LED flashes
"2" then press "SET" button.
It's now under force adjustment mode. The LED
displays the current set force.
Press "UP" button to increase the force and "DOWN" button
to decrease the force. The maximum force is 9 and the
minimum is 1
Press "SET" button to confirm, the opener returns to standby
mode.
The default setting of safety force is 5.
Press and hold on "SET" button for 3 seconds until the
LED flashes "1" Press "UP" or "DOWN" button until the
LED flashes "3", press "SET" button, it's now under
photo beam setting mode. The LED displays the current
setting.
Press "UP" button, the LED displays "1", the photo
beam function is available. Press "DOWN" button the
LED displays "O" to cancel this function. Press "SET"
button to confirm. The opener returns to standby mode.
The default setting of photo beam is "O".
NOTICE: Close the photo beam function when you don't
use photo beam sensor.
Press and hold on "SET" button for 3 seconds until the LED
flashes "1".
Press "UP" or "DOWN" to increase or decrease, adjust the
LED to flash "4", then press "SET" button to enter into
auto-close setting. The LED displays the current setting.
Press "UP" or "DOWN" button to adjust the auto-close time
press "UP" button once, the auto-close time will increase
1 minute, the maximum time is 9 minutes.
Press "DOWN" button once, the auto-close time
decrease 1 minute. The auto-close function will be turned
off when the LED display "O". Press "SET" to confirm, the
opener returns to standby mode.
The auto-close function can only be available when the
door is fully open and the photo cell beam function is on.
The default setting is "O"