Download Print this page
Fronius TransPocket 150 Update Procedure
Hide thumbs Also See for TransPocket 150:

Advertisement

Quick Links

Update procedure TransPocket 150/180 + PN´s
TransPocket 150/EF (4,075,210), TransPocket 150/np (4,075,210,008), TransPocket 150 RC/EF (4,075,211),
TransPocket 150 TIG/EF (4,075,212), Transpocket 150/CH (4,075,210,003), TransPocket 150/G
(4,075,210,002), TransPocket 180/EF (4,075,213), TransPocket 180/np (4,075,213,008), TransPocket 180
MV/np (4,075,213,638), TransPocket 180/CH (4,075,213,003), TransPocket 180 MV/G (4,075,213,632),
TransPocket 180 RC/EF (4,075,214), TransPocket 180 TIG/EF (4,075,215), TransPocket 180 TIG/MV/B
(4,075,215,631), TransPocket 180 TIG/MV/np (4,075,215,638)
09/2018
1) You have to open the control board, unscrew this 2 screw to open
it.
Screwdriver Torx - T25 VDE (42,0435,0041)
2) On the inside of the control board you can see the port for the
USB 2.0 Micro B cable
3) Connect the USB 2.0 Micro B cable with the control board
Datum: 19.09.2018
Zeichen:
1/7

Advertisement

loading

Summary of Contents for Fronius TransPocket 150

  • Page 1 Datum: 19.09.2018 Zeichen: Update procedure TransPocket 150/180 + PN´s TransPocket 150/EF (4,075,210), TransPocket 150/np (4,075,210,008), TransPocket 150 RC/EF (4,075,211), TransPocket 150 TIG/EF (4,075,212), Transpocket 150/CH (4,075,210,003), TransPocket 150/G (4,075,210,002), TransPocket 180/EF (4,075,213), TransPocket 180/np (4,075,213,008), TransPocket 180 MV/np (4,075,213,638), TransPocket 180/CH (4,075,213,003), TransPocket 180 MV/G (4,075,213,632),...
  • Page 2 4) Connect the USB plug to the Laptop It could be that you can´t get a connection with that cable, although the plug is inside the USB port. In this case, you have to install the USB driver (CDM included in the ZIP file) Disconnet ALL other cables (power supply, mains plug, other USB cables) ...
  • Page 3 7) After you opened the Service Tool, Switch ON the power source 8) To select the right COM Port you have first to open the devices manager (to open the devices manager you have to click with the right mouse button on the windows symbol on the bottom left in the corner and select device manager) 09/2018...
  • Page 4 9) When you have opened the device manager, you should see this window. Now open the option Connections, to see the available COM ports. 10) The opened Option „Connections“ shows you the available COM ports, so you can see what COM you have to select in the ServiceTool.
  • Page 5 11) Select the right COM port 12) After selecting the COM port, press „Connect“ 09/2018...
  • Page 6 13) Selection of the correct configuration based on the rating plate of the machine. The Service Tool already makes a pre-selection of the machine type, TP 150 or TP 180 then you just need to select which variant you have: Standard, MV and the socket type (FUSE settings) 14) When you see this window opened, the upload is already running.
  • Page 7 15) Press ok and close the Service Tool. Upload finished! !! Perform a reboot (switch OFF & ON) at least twice after the update!! 1) With the following steps you can check the Software update direct on the power source. After this steps you should see the uploaded version of the software on the display 09/2018...

This manual is also suitable for:

Transpocket 180Transpocket 150/efTranspocket 150/npTranspocket 150 rc/efTranspocket 150 tig/efTranspocket 150/ch ... Show all