AMG AMG4644ER-SF Instruction Manual

AMG AMG4644ER-SF Instruction Manual

4 channel video receive unit with bi-directional data channel plus ethernet for a multimode single fibre link

Advertisement

Quick Links

4 Channel Video Receive Unit with Bi-directional Data
Channel plus Ethernet for a Multimode Single Fibre Link
The AMG4644ER-SF is a rackmount four channel video receive unit designed to receive 4 video
signals and transmit and receive 1 data signal plus full duplex 100BaseT Ethernet connectivity over
one Multimode fibre.
The AMG4644ER-SF is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits
into a 19" rack system.
The AMG4644E-SF is designed to operate with AMG4643E-SF or rackmount equivalent
AMG4643ER-SF four channel video transmit unit in a point to point configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
AMG4644ER-SF
Instruction Manual
Page 1 of 8
AMG4644ER-SF Instruction Sheet
D18604-01.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMG4644ER-SF and is the answer not in the manual?

Questions and answers

Summary of Contents for AMG AMG4644ER-SF

  • Page 1 1 data signal plus full duplex 100BaseT Ethernet connectivity over one Multimode fibre. The AMG4644ER-SF is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19" rack system. The AMG4644E-SF is designed to operate with AMG4643E-SF or rackmount equivalent AMG4643ER-SF four channel video transmit unit in a point to point configuration.
  • Page 2: Table Of Contents

    Removal / replacement from / to the Case..................8 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 8 AMG4644ER-SF Instruction Sheet document without notice. The information herein is believed to D18604-01.doc...
  • Page 3: Introduction

    Ethernet connectivity is also provided between the two units. Optical Connection The AMG4643E-SF is connected as illustrated below when used with an AMG4644ER-SF rackmount receive unit acting as a point to point system. AMG Systems Ltd. reserves the right to make changes to this...
  • Page 4: Connections

    RS485 – switch position – low (furthest from BNC connections) DATA CHANNEL B Data Channel B ........Not Present AMG Systems Ltd. reserves the right to make changes to this Page 4 of 8 AMG4644ER-SF Instruction Sheet document without notice. The information herein is believed to D18604-01.doc...
  • Page 5: Data And Audio Channel Configuration

    RS485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
  • Page 6: Front Panel Indicators

    OUT+ logic one (-V) present on OUT+ This represents the data signals being received on the optical fibre AMG Systems Ltd. reserves the right to make changes to this Page 6 of 8 AMG4644ER-SF Instruction Sheet document without notice.
  • Page 7: Ethernet Operation

    Ethernet Operation In order for the AMG system to transmit Ethernet signals, an onboard RJ45 Ethernet interface or X16003 Ethernet interface adaptor should be fitted to both the Transmit unit and the Receive unit. The Ethernet interface can operate at either 10Mbits/s half duplex, or 100Mbit/s full duplex, and data is transmitted from one port the other port with the minimum of delay or buffering.
  • Page 8: Physical Information

    There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.

This manual is also suitable for:

Amg4644e-sfAmg4643e-sf

Table of Contents