For DuraVent pipe only: Install vent pipe by aligning the
locking system together, sliding the pipes together and
twisting clockwise.
• Install 90° elbow. Twist lock as before.
• Slide the wall plate over horizontal run before
attaching the horizontal run to the elbow. Fasten wall
plate to wall.
4. For Hearth & Home Technologies Vent Pipe only: If
necessary, measure to determine the vertical length (X)
of pipe required from the adapter pipe to the wall cutout
centerline, including a 2" (51mm) overlap at the joint.
(Figure 24) use a hacksaw or tin snips to trim the pipe as
needed.
Figure 24 - Determine the vertical pipe length.
5. Install first the inner then the outer straight pipe section(s),
trimmed end down, to the point of the elbow. Drill 3 holes
through each joint and fasten with sheet metal screws.
6. Seal and install the elbow using 3 sheet metal screws at
each joint.
7. Measure, and cut if needed, the appropriate length of
pipe section needed to make the connection through
the wall. Include a 2" overlap; i.e. from the elbow to the
outside wall face, about 2" or the distance required if
installing a second 90° elbow. (Figure 25)
8. Slip the wall plate and trim collar over the interior end of
the horizontal pipe and install into the wall sleeve. Seal
the joint inside the wall plate if needed to keep cold air
from being drawn into the home.
9. Seal the ends and connect the horizontal pipe to the
elbow. Fasten the wall plate to the pipe with three sheet
metal screws. Slide the trim collar up against the wall
plate to cover the screws. (Figure 26)
3-90-693831
Hearth and Home Technolgies • Oxford Direct Vent Installation Manual_R6 • 08/17
X
ST764
DW
measure vertical vent
5/15/03 djt
X
Figure 25 - Measure the horizontal length.
Wall
Sleeve
Figure 26 - Install the horizontal pipe and wall plate parts.
10. For both Hearth & Home Technologies and
DuraVent Systems: Install the vent terminal. (Figure
ST216
27) Apply high temperature sealant one inch from the
install pipe thru wall
ends of the inner and outer collars. Guide the inner and
outer vent termination collars into the adjacent pipes.
12/6/99 djt
Double check that the vent pipes overlap the collars by
2". Fasten the termination to the wall with the screws
provided, and caulk the joint with weatherproof sealant.
11. For Hearth & Home Technologies only: Install
Charcoal Gray Pipe Rings or Polished Brass Pipe Rings
at pipe joints, if desired.
Seal Both
Terminal Ends
Caulk Plate Joint with
Weatherproof Sealant
Figure 27 - Install the vent terminal.
ST217
install wall terminal
12/6/99 djt
Trim Collar
ST215
measure thru wall
12/6/99 djt
Wall Plate