Technibel GRF78R5TAA Technical Data & Service Manual page 6

Table of Contents

Advertisement

GRF98R5TAA
Power source
Voltage rating
Performance *
Capacity
Air circulation (High)
Moisture removal (High)
Electrical Rating
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Features
Fan speed
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Power noise level
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant
tube diameter
Dimensions & Weight
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks:
Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
*
For other INDOOR UNITS' MODELS, please refer to catalogue
MRAF98R5TAA
kW
BTU/h
m³/h
Liters/h
V
A
W
%
W/W
A
g
Hi
dB-A
m
Narrow tube
mm(in.)
Wide tube
mm(in.)
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
Net
kg
Shipping
kg
3
m
6
220 - 240V ~ 50Hz
230V
Cooling
2,65
9040
450
1,2
Cooling
198 ~ 264
3,50
770
96
3,44
17
1(Hi)
Rotary (Hermetic)
R410A / 850
Capillary tube
57
Flare type
7,5
6,35 (1/4)
9,52 (3/8)
540
700
265
568
815
343
35,0
38,0
0,16
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Heating
3,00
10230
-
Heating
3,60
790
95
3,80
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grf98r5taaGrf128r5taa38.7107.08038.7107.08138.7107.082