Hot -Swap procedure
Please carry out following procedure if one of the power supply module is
defective.
1. The blinking of the system power supply LED indicate a failure of the
redundant power supply unit.
2. If the system is integrated in a rack, remove at first the unit to have access to
the back side of the PxV206 – 2U Platform (loosen the 4 screws for in rack
mounting).
3. Locate the defective power supply module by examining the status of DC
power status LEDs of the redundant PSU.
4. Unscrew and remove the defective PSU module.
5. Replace by inserting the new (a good one) PSU module into the PSU chassis
and screw it on.
6. Check the DC OK LED which indicate the power supply status; that should be
lighting.
7. Replace the PxV206 – 2U Platform into the rack (if the system is integrated in
a rack.
PxV206 – 2U Platform – User's Manual