Kontron Embedded Computers PxV206 User Manual page 23

2u platform
Table of Contents

Advertisement

Product Description
Behaviour of the PxV206 – 2U Platform equipped with a redundant PSU
System
System
PSU
power
power
power
switch
LED
switch
Off
Off
On
On
On
On
On
blink
On
On
blink
On
If a failure occurred and one of the PSU modules is defective, the redundant PSU
LED start to blink and a beep is audible. The DC–Power status LED from the
defective redundant PSU module is not on.
The PxV206 2U Platform is continuing to operate with one of the power supply
modules.
By press of the PSU alarm reset button the beep will be interrupt, but the
redundant PSU LED is still blinking till the defective power supply module was
changed with a good one.
The redundant PSU LED is in a one to one connection with the system power
LED (located at the front panel).
22
PSU
Redundant PSU
power
Module 1
LED
AC OK
DC OK
On
On
Off
On
On
On
blink
On
Off
blink
On
On
PxV206 – 2U Platform – User's Manual
Module 2
AC OK
DC OK
On
Off
PSU is On
but the
system is
not working
On
On
The system is
operating
On
On
The system is
operating with
one defective
PSU
On
Off
The system is
operating with
one defective
PSU
System
status

Advertisement

Table of Contents