Dr. A. Kuntze Neon pR Manual
Hide thumbs Also See for Neon pR:
Table of Contents

Advertisement

Quick Links

Dr. A. Kuntze
manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Neon pR and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr. A. Kuntze Neon pR

  • Page 1 Dr. A. Kuntze manual...
  • Page 2: Table Of Contents

    Menu appearance depending on code and options ..........29 Code ..........................30 Mode ..........................31 Analog input – pH or ORP measurement ..............32 Temperature measurement ...................33 Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 3 12.7. Reset to factory settings ..................57 12.8. Add-on activation ....................58 13. Alarm relay ........................59 13.1. Settings ........................59 13.2. Alarm action ......................60 14. Add-on Datalog ......................61 Robert-Bosch-Str. 7a Dr. A. Kuntze Gutes Wasser mit System 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 4 16.1. How to read out data ....................66 16.1.1. Definition Read Holding Registers ..............66 16.1.2. Communication parameters ................66 16.1.3. Register......................67 17. Operation and Maintenance of Neon pR ...............68 17.1. Mode ........................68 17.2. Maintenance of the measurement ................68 17.2.1. Cleaning of sensors ..................69 17.2.2.
  • Page 5 Content 18.8. Events with Popup messages ................91 18.9. Reset ........................92 Index ............................93 Robert-Bosch-Str. 7a Dr. A. Kuntze Gutes Wasser mit System 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 6: Your Neon

    1. Your Neon 1. Your Neon is an instrument by Dr. A. Kuntze GmbH which offers high quality and long-term reliability, made in Germany. With its modular design, the Neon instrument can be tailored to your application. The entry-level version contains inputs for measurement and temperature, a digital input, and an alarm relay.
  • Page 7 – we will be delighted to help you! Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 8: General And Safety Instructions

    1. Your Neon 1.1. General and safety instructions This operation manual applies to the following instruments Instrument type Neon pR SW version V 2.03 The manual contains technical information on installation, operation, and maintenance. Keep this manual in a place where you can always look up the safety instructions and the information on handling and usage.
  • Page 9: Warranty Conditions

    We have to point out that the warranties specified in our trading conditions are valid only if the following conditions are met:  Installation and start-up by Dr. A. Kuntze personnel or trained and authorized technicians  Maintenance of instrument and peripherical equipment according to the instructions of this manual ...
  • Page 10 The safety of the system of which the instrument is part of lies within the reach of responsibility of whoever built the system! Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 11: Intended Use

    Use these instruments only for the monitoring and control of water – or, in case of gas monitoring instruments, of ambient air. Use only sensors, assemblies, and accessories made by Dr. A. Kuntze, and make sure that they fit your application. Make sure that the required measuring conditions such as flow, pressure, temperature etc.
  • Page 12: Features

    SD card To save the diagnosis file To load software updates Auto lock Resets the code to 0000 after a defined period of time Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 13 Interval adustable between 1 second and 24 hours Ring or Stop mode Digital interface Modbus RTU, 19200 bps, 8 Bit, 1 Stop-Bit, even parity Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 14 Max. frequency 2 potential-free contacts 6A, 250 V, max. 550 VA Relay 1 – control variable Relays Relay 2 – circulation pump Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 15: Technical Data

    250 V, 6A, 550 VA Operation temperature 0.. 50°C Storage temperature -20.. +65°C Rel. humidity max. 90% rH at 40°C (non-condensing) Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 16: Instructions For Installation And Connections

    Note Mind the protection class! 2.1. Dimensions Picture 1 Dimensions Neon panel-mounted housing Picture 2 Dimensions Neon wall-mounted housing Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 17: Installation Panel-Mounted Housing

    Attention To preserve the protection class, the flat gasket of the housing and the sealing ring of the frame must be used! Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 18: Installation Wall-Mounted Housing

    Or you can open the instrument and put the screws through the holes at the back of the instrument. Mind to replace the covers before closing the instrument. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 19: Connections

    When using the relays, mind that with inductive loads, interference must be suppressed. If that is not possible, the relay must be protected at the terminal block by a resistance-capacity filter or, in case of direct current, by a free-wheeling diode. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 20: Connection Diagram

    9 = T2 (Pt 1000) – 3-wire connection/cable compensation Digital input 1 50+51 50 = +, 51 = -, low water, level monitoring, or controller stop Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 21 ┴ ┴ = Screen Add-ons (marked in grey) Controller or volume-based dosing, second digital input, up to 2 mA outputs, data logging, and RS Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 22: Operation

    In the bottom line, the triangular symbol shows the way to the menu (key DOWN, or just touch the triangle if you have a touch screen instrument). On the right side of the bottom line, current events are displayed. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 23: Key Pad Operation

     OK – opens the selected (dark) submenu or changes the mode  ESC – retraces the last step  DOWN – moves to the adjacent symbol  UP – moves to the adjacent symbol in the other direction Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 24: Submenus

    UP and DOWN, the scroll bar follows automatically. Select a parameter with the OK key to enter a value or select a setting from a drop-down list. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 25: Touch Screen Operation

    In that case you have to enter the main menu and set a valid code first (0202 for the calibration level, 1612 for full access) Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 26: General

    Move the scroll bar by pulling the bar with your finger or by touching the triangles at the top and bottom of the bar. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 27: Settings

    Press ESC if you want to cancel and leave without changing the setting. Action lists Action lists appear whenever you can select more than one option from a list, for example alarm actions: Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 28 Parameters that do not fit to previous selections are marked as ----- and cannot be edited. Example: have selected automatic temperature compensation, setting manual value unnecessary. Accordingly, the box shows ----- and cannot be edited. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 29  The „AC“ (all clear) key erases the complete input  The „OK“ acknowledges the selection Note With numerical parameters, the keyboard automatically shows only numbers. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 30 4, for example, is automatically turned into 4.00, and an input of 1 for the datalog interval is automatically interpreted as 00:00:01 (hours:minutes:seconds). Unfortunately, for date, code, add-on codes, text, and contact data, this support is not feasible. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 31: Menu Overview - Where To Look

    3. Operation 3.5. Menu overview – where to look? Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 32 3. Operation Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 33 3. Operation Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 34: Menu Appearance Depending On Code And Options

    With code 0202, access is restricted, and the number of symbols decreases. If you use the Neon for ORP measurements, all unnecessary submenus disappear, such as the CAL symbol in the main menu. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 35: Code

    0000, to prevent unauthorized operation, after a defined interval without operation, or whenever the power supply was cut off. For more information, see the chapter “System functions”. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 36: Mode

    The instrument shows always only the features that you have purchased. In the entry-level version, the instrument contains the desktop, the alarm relay, the test functions, and the limits. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 37: Analog Input - Ph Or Orp Measurement

    Select Koax for common pH sensors with or without integrated temperature sensor. Mind that the sensor and sensor connection must fit the setting. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 38: Temperature Measurement

    In the automatic mode, the measured temperature values are used to compensate the temperature influence on the measurement, and in the manual mode, a manual temperature setting is used. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 39: Dr. A. Kuntze I Gutes Wasser Mit System

    Note If you do not want to compensate the pH-value, choose the same temperature values for reference and manual value. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 40: Temperature Compensation - Orp Measurement

    If you have no temperature sensor connected, select manual compensation, and enter the temperature manually. This value will then be displayed on the desktop and be given out via the various interfaces. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 41: Menu Cal - Calibration - Ph

    Here you find three symbols: run, info, and settings. Note If you have selected ORP measurement, the symbol CAL is not shown, since the ORP measurement cannot be calibrated. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 42: Calibration - Run

    OK.  With the OK button you execute the first calibration point and reach the second step of the calibration process. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 43 Refer to the eventlog or the chapter “Trouble shooting” for more information. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 44: Calibration - Info

    The temperature compensation compensates only the temperature influence on the measurement, not on the buffers! Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 45: Digital Inputs

    If you have activated the add-on Volume-based Dosing, then the second digital input is used for the flow measurement. In that case no symbol for the second digital input appears. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 46: Test Menu

    0.00 and 22.00 mA. This value is then sent out via the selected analog output. Note When you leave the menu, all relays and all analog outputs are reset to their previous settings. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 47: Memory

    Settings can be duplicated only to instruments of the same type, and in case of pR instruments only if they are set to the same parameter, i.e. either pH or ORP. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 48: How To Save Settings

    Acknowledge with OK. The display shows the name of the created file. The name consists of the parameter and the date, for example pH210812_2339.set. Acknowledge with OK. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 49: How To Load Settings

    After installation, the instrument initializes. During that process, the time is displayed on the desktop. Note You can only load settings files for the same parameter. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 50: Software Update

    Acknowledge with OK. Progress is indicated by a status bar. After installation, the instrument initializes. During that process, the time is displayed on the desktop. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 51: How To Save The Diagnosis File

    Acknowledge with Note The .dia file is a binary file and can only be read with an appropriate configuration program. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 52: System Functions

    To change the language, select the symbol SYSTEM in the main menu and in the submenu the symbol LANGUAGE. A drop-down list shows all languages that are available on your instrument. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 53: Time

    12.3. Display All settings concerning the display are found in the submenu SYSTEM=>DISPLAY. If you have a touch screen instrument, the touch screen calibration is also found in this submenu. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 54: Settings

    With touch screen instruments, you can switch the display design by touching the instrument name on the desktop. To ensure that this selection is permanent, set the Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 55 This adds a status bar indicating the remaining storage space on the SD card. Selection: Contact This adds the contact data that is stored in the submenu SYSTEM=>CONTACT. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 56 Autolock sets the code back to 0000, and the display shows the desktop with the measured values. If you set the interval to 0, the autolock function is deactivated. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 57 Text Here you can enter an identification or location, which will be shown on the left side of the top line of the desktop. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 58: Touch Cal -For Instruments With Touch Screen

    Step 4 Step 5 Note The touch screen calibration can also be started by touching the screen for more than 30 seconds. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 59: Contact

    Contact data can be shown on the desktop, if you select the display design “Contact”. Note With restricted access (Code 0202) you can view this menu but not change the settings. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 60: Event-Related Support

    If there are no event messages, the event help will only show “no active event”. If more than one event is currently indicated, you can scroll up and down to view all events. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 61: Info

    Note The analog outputs and the second digital output are add-ons, and are shown only if the instrument is equipped with these features. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 62: Reset To Factory Settings

    All settings are reset, and the instrument initializes. Note With touch screen instruments, the touch screen has to be calibrated after reset. The calibration routine starts automatically. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 63: Add-On Activation

    If the entered code was incorrect, no message appears, and the previous settings are maintained. Note We recommend to reset all settings to factory settings after activating add-ons. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 64: Alarm Relay

    Here you can turn the normally open contact into a normally closed contact. That means that the relay is actively closed in case of normal operation and opens in case of alarm – with the advantage that power failure also leads to an alarm. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 65: Alarm Action

    The following events always cause the alarm relay to switch:  Communication error  Unknown measuring module Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 66: Add-On Datalog

    You decide which parameters are logged. Tick the boxes to log the parameter. Log set In the submenu LOG SET you can make the following settings: Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 67 Note The instrument fills in zeros automatically. Example: 1 is interpreted as 00:00:01 / 1: is interpreted as 00:01:00 / 1:1: is interpreted as 01:01:00 Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 68: View Logged Data

     Power was turned off  The measuring parameter changed, for example from pH to ORP  The logging was stopped and restarted  Other parameters for the datalogging were selected Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 69: Add-Ons Ma Output

    20mA. With these settings you can even invert the output, by assigning 20mA to a smaller value than 0/4mA. In case of controller output the output is in %, so you cannot set range min and max. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 70: Add-On Modbus Rtu

    Bus termination If you select ON from the drop-down list, the termination is activated for this instrument. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 71: How To Read Out Data

    N* x 2 Bytes *N = Quantity of Registers 16.1.2. Communication parametersrs Baudrate: 19200 bps Data bits: Stopp- Bits: Parity: even MODBUS Adress: 16|dec Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 72: Register

    Secondary Value: Register 20 Raw Value: Register 30: Raw Value Input 1 Register 31: Raw Value Input 2 Dig I/O: Register 40: Digital I/O Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 73: Operation And Maintenance Of Neon Pr

    17. Operation and Maintenance of Neon pR 17. Operation and Maintenance of Neon pR 17.1. Mode Never carry out maintenance while the controller is set to automatic. Select either manual mode or Hold. In the manual mode only the controller is deactivated. All other functions such as the alarm relay and the test functions are still active.
  • Page 74: Cleaning Of Sensors

    17. Operation and Maintenance of Neon pR 17.2.1. Cleaning of sensors Handle and clean sensors very carefully. Always use water and perhaps a soft paper tissue as the first cleaning agent. The pH-sensitive glass bulb of pH sensors is very thin and must not be mechanically damaged.
  • Page 75: Cleaning Of Assemblies, Filters, Etc

    17. Operation and Maintenance of Neon pR 17.2.3. Cleaning of assemblies, filters, etc. An important part of maintenance is the cleaning of all parts that come in contact with the water. Besides the sensors, this includes assemblies, pipes and tubes, filters, flow meters, cocks, valves etc.
  • Page 76: Exchange Of Consumables

    17. Operation and Maintenance of Neon pR lead to the text message “low water” or “level” or “ext. controller stop” according to settings, and to an automatic controller stop. Regularly test the function of the alarm relay and ensure that in case of an alarm, the instrument issues the alarm and the connected control center registers the alarm correctly.
  • Page 77: Restarting

    17. Operation and Maintenance of Neon pR 17.3. Restarting Restarting is to be carried out like the original start-up. Follow all steps described in this manual. Before opening the water inlet, make sure that the flow is not impeded or interrupted anywhere.
  • Page 78: Decommissioning And Disposal

    17. Operation and Maintenance of Neon pR 17.4. Decommissioning and disposal If you want to take the measurement out of service for a while, mind the storage conditions listed in the data sheets, especially regarding temperatures. Store sensors always in solution, preferably in 3M KCl, never in deionized water or aggressive solutions.
  • Page 79: Facilitating Functions

    17. Operation and Maintenance of Neon pR 17.5. Facilitating functions 17.5.1. Store and load settings via SD card You can store your settings on an SD card and reload them anytime to ensure that the settings are not lost during maintenance.
  • Page 80: Trouble-Shooting

    If it has vanished, the sensor needs to be replaced or at least cleaned and regenerated.  Spare cable: Cables are frequently causing trouble – damaged contacts or insulations lead to malfunctions very similar to those caused by sensor Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 81: Contact

    Note You can have the contact data displayed on the desktop, if you “contact” select desktop design menu SYSTEM=>DISPLAY. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 82: Diagnosis File

    If for example you get a slope error after calibration, even though the raw signals of the sensor were plausible, then the problem might well be a Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 83: Event Messages

    This helps to interpret events – for example a deviation of the measured value shortly after a power interrupt may simply be due to the unfinished polarization of the measurement. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 84: Event Help

    These can be found in the menu SYSTEM=>EVENT, or – with touch screen instruments – by touching the event message on the desktop. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 85 If the internal buffer is pH 7, then a calibration buffer of pH 7 should yield a signal around 0 mV. Deviations of less than 1 pH (approx. 60mV) are tolerated. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 86 If the sensor still looks normal, it is worth the trouble to empty and refill it with fresh 3M KCl solution. Wait 24h and then check the zeropoint again. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 87 A low slope can also be the result of contact problems, or more accurately if the insulation is not as high as it has to be. Damaged cable insulations, or water inside Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 88 Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 89 Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 90 As with the measuring input, a defective cable or sensor can be the cause for this message. You can check temperature sensors with an Ohmmeter – a Pt100 has a resistance of approx. 109 Ohm at room temperature, a Pt1000 approx 1080 Ohm. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 91 If the message occurs shortly after start-up and possibly quite frequently, please check the settings for control and limits to make sure that they match both each other Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 92 Note If you have activated a second digital input, this will lead to similar messages, starting with „digital input 2“. Further messages with activated add-ons: Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 93 Cause Suggested remedies Dosage check Controller ouput was 100% Check dosing, especially feed for longer than the lines and pump specified time Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60 www.kuntze.com...
  • Page 94 This message appears if you have activated Volume-based dosing and the flow exceeds the measuring range of the flow sensor. Since control is not possible under these conditions, dosing has been stopped. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 95 If such a message appears, the instrument has to be sent in for repair. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 96 If you have set the logger to STOP mode, then the instrument stops the logging when the SD card is full. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a 40668 Meerbusch +49 (0) 2150-7066-0 / Fax -60...
  • Page 97 With the Reset function, the system is set to a defined condition. User settings that might severely impede an evaluation of the measured values, such as a calibration gone wrong, are erased. Dr. A. Kuntze Gutes Wasser mit System Robert-Bosch-Str. 7a...
  • Page 98 Index data contact person Contact (digital input) Access levels Contrast (display) Add-on activation Correction (temperature) Alarm action Alarm relay action list Data log delay interval function start limit values view settings Decommissioning Analog input Delay (alarm) Analog outputs Desktop 17, 49 0/4-20mA selection Diagnosis file 46, 77...
  • Page 99 Menu overview Modbus RTU Hold bus address bus termination communication parameters read holding registers Info register calibration Mode (data log) menu 56, 77 Mode (operation mode) 31, 68 Installation Mode (temperature compensation) panel-mounted housing wall-mounted housing Internal buffer Interval (data log) No appli IWA 11.4 Operating hours...
  • Page 100 Restarting Temperature compensation 33, 34 Restoring factory settings reference temperature RS 485 off Temperature measurement correction sensor type Test menu 41, 74 Save Text diagnosis file Time settings Touch Calibration SD card Touch screen operation SD card error Trouble-Shooting Serial number Type (temperature measurement) Settings alarm relay...
  • Page 101 Robert-Bosch-Str. 7a I D-40668 Meerbusch I Germany Fon +49(0)2157066-0 I Fax +49(0)21507066-60 info@kuntze.com I www.kuntze.com...

Table of Contents