14
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
15
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
ECO SLEEP OPERATION
16
For ECO sleep automatically control air fl ow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
17

MAINTENANCE

Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
No benzine, thinner, polishing powder or chemically-treated duster.
Air fi lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air fi lter.
3. Vacuum or wash and then dry them.
4. Reinstall the air fi lters and close the air inlet grille.

SELF CLEANING OPERATION

18
(COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.
19

OPERATION AND PERFORMANCE

1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Cooling
-10°C ~ 46°C
Dry
-10°C ~ 46°C
more 2 times within
Room Temperature
21°C ~ 32°C
17°C ~ 32°C
@TeddyAir 095-323-9555
www.TeddyAirCond.com
20

TROUBLESHOOTING (CHECK POINT)

The unit does not operate.
The power main switch is
The filters are blocked with dust.
turned off.
T h e t e m p e r a t u r e h a s b e e n s e t
The circuit breaker is
improperly.
activated to cut off the power
The windows or doors are opened.
supply.
The air inlet or outlet of the outdoor unit
Stoppage of electric current.
is blocked.
ON timer is set.
The fan speed is too low.
The operation mode is FAN or DRY.
21
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. "00" will be shown on the display.
MODE
4. Press
during pushing
"00" will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
Cooling is abnormally low.
. "B" will show on the display and
2

Advertisement