Ring terminals
8.
Unfix the sheet copper for fixing the pressure switch hose. (see pressure switch removal
and replacement)
9.
Remove two screws for fixing spray holder, then take out the spray holder.
Screws
Part name: 1 – sprayer holder 2 – nut of sump assembly
10. Turn cover of water softener. Contrarotate nut of air breather. Contrarotate nut of siphon,
then take out one way valve from siphon. Contrarotate nut of sump assembly.
Part name: 1 – nut of air breather 2 – nut of siphon
3 – nut of water softener 4 – nut of sump assembly
11. Take out door springs and connecting lines for connecting spring to door assembly.
12. Remove all screws for fixing right and left front chamber bracket. Take out the tank
assembly, at the same time unfix the snap-fits of bottom board for fixing right and left front
chamber bracket.
Part name: 1 – springs 2 – connecting lines
3 – right front chamber bracket
Plug terminal of
tank assembly
Screw and nut
1
2
1
2
3
4
1
2
3
4
Snap-fits
Screws