2.1.14 Removing the Top Panel
1. Open the door. (Refer to 2.1.2.)
2. Remove the side panel. (Refer to 2.1.7.)
3. Remove the two blind bolts
&
4. Remove the six screws
16
17
2.1.15 Removing the U/D Motor
1. Remove the top panel. (Refer to 2.1.14.)
*
2. Remove the screws
and two screws
)
3. Loosen the two screws
sliding it toward the door side.
18
4. Disconnect the two connector cables from the U/D motor.
5. Remove the U/D belt to remove the U/D motor.
Connector cable
2-9
^
using a coin, etc.
to remove the top panel.
17
(
.
, and pull out the U/D motor by
19
20
U/D Motor Ass'y
Belt
2.1.16 How to Operate with the Door Open (for Servicing)
For safety this unit is designed so as not to be operated with
the door open. When operating the unit with the door open for
maintenance or servicing, proceed in the following manner.
1. Open the door. (Refer to 2.1.2.)
2. Remove the two interlock release bars on the center panel
which turns the interlock switch to ON.
3. With the door open, insert the interlock release bars into the
interlock switch holes located at both the left and right sides.
Interlock Release Bar
4. With this operation, the unit enters the mode in the same
way as with the doors closed, and you can operate the unit
as normally.