Vision & Control SLF-100-W5K7-P-24V Instructions For Use Manual

Compact spot light, colour temperature: white - 5700 k

Advertisement

Quick Links

creating machine vision
Instructions for Use
Instructions for Use
SLF-100-W5K7-P-24V
SLF-100-W5K7-P-24V
Compact spot light,
Compact spot light,
Colour temperature: White - 5700 K
Colour temperature: White - 5700 K
999.995.400.10-en-1.3
© Vision & Control GmbH 2021
VISION & CONTROL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLF-100-W5K7-P-24V and is the answer not in the manual?

Questions and answers

Summary of Contents for Vision & Control SLF-100-W5K7-P-24V

  • Page 1 VISION & CONTROL Instructions for Use Instructions for Use SLF-100-W5K7-P-24V SLF-100-W5K7-P-24V Compact spot light, Compact spot light, Colour temperature: White - 5700 K Colour temperature: White - 5700 K 999.995.400.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 2 Impress Publisher / Manufacturer Vision & Control GmbH Mittelbergstraße 16 98527 Suhl, Germany Telephone: +49 (0) 3681 7974-0 Telefax: +49 (0) 3681 7974-33 www.vision-control.com Name of the document 999.995.400.10-en-1.3 Date of first issue 2020-10-26 Date modified 2021-05-03 Copyright © Vision & Control GmbH 2021 Copyright It is forbidden to pass this document on to third parties, reproduce and communicate its contents in as far as this has not been expressly authorized.
  • Page 3 Validity These instructions for use are valid for the following device: Device Order no. SLF-100-W5K7-P-24V 1-33-346 Product Identification Designation Description Compact spot light - Attachment optics with frosted lens Luminous field diameter in mm at 200 mm Working distance W5K7...
  • Page 4: Table Of Contents

    SLF-100-W5K7-P-24V Table of Contents TABLE OF CONTENTS 1 Information about the Instructions of Use..........5 1.1 Intended Use....................5 1.2 Improper Use....................6 1.3 Qualified Personnel..................6 1.4 Warranty and Liability...................7 2 Safety......................8 2.1 Presentation of Safety Instructions.............. 8 2.2 Safe Handling of the Device................ 9 3 Scope of Delivery and Accessories............
  • Page 5: Information About The Instructions Of Use

    SLF-100-W5K7-P-24V Information about the Instructions of Use 1 INFORMATION ABOUT THE INSTRUCTIONS OF This document contains technical information, important instructions for correct installation, commissioning and use, as well as product information which were up-to-date at the time of going to press.
  • Page 6: Improper Use

    SLF-100-W5K7-P-24V Information about the Instructions of Use 1.2 Improper Use All unintended use and all device-related activities not described in these instructions of use is to be deemed as unauthorised misuse outside the legal limits of indemnity of the manufacturer.
  • Page 7: Warranty And Liability

    SLF-100-W5K7-P-24V Information about the Instructions of Use 1.4 Warranty and Liability The contents of this document have been checked carefully and correspond to current legislation and best practise at the time of going to press. However, the manufacturer shall not be liable for any damage arising from the use of this edition of the manual, and rejects any warranty derived therefrom.
  • Page 8: Safety

    SLF-100-W5K7-P-24V Safety 2 SAFETY 2.1 Presentation of Safety Instructions Each safety instruction is introduced by a key word and colour highlighted. The key word indicates the degree of danger. The danger and its cause are described, and then the measures to prevent conceivable consequences of the danger.
  • Page 9: Safe Handling Of The Device

    SLF-100-W5K7-P-24V Safety 2.2 Safe Handling of the Device Read the following applicable safety instructions carefully and completely. Follow the instructions for your own safety, the safety of other people, and to avoid damage to the device and the connected technical equipment. Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual.
  • Page 10: Scope Of Delivery And Accessories

    Because of the many possible configurations, the cables are listed in the accessories rather than included in the scope of delivery. 3.1 Scope of Delivery Designation Quantity Device SLF-100-W5K7-P-24V Instructions for Use SLF-100-W5K7-P-24V 3.2 Accessories Connection cable M8-4-pin, straight plug, 4A, 60V Designation Description Order no.
  • Page 11 SLF-100-W5K7-P-24V Scope of Delivery and Accessories Connection cable M8-4-pin, straight plug, 5A, 30V Designation Description Order no. Connection cable Connection cable with 4-pin M8 socket 1-11-611 M8-4pin, 1m and open cable end with wire-end ferrules, 4 x 0.5 mm², 5A, 30V, PUR,...
  • Page 12: Device Description

    SLF-100-W5K7-P-24V Device Description 4 DEVICE DESCRIPTION 4.1 Device Views Image 1: Device view Casing Light-emitting surface Filter thread M28x0.5 - depth: 5 mm Mounting hole M3x0.5 - depth: 4.5 mm Mounting hole Ø4.2 - through bore Connector M8-4pin 999.995.400.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 13: Notices On The Device

    SLF-100-W5K7-P-24V Device Description 4.2 Notices on the device Following instructions are provided on the device: Type.: XXXXXXXXX No.: TTTJJNNN Notes on power supply Device designation Serial number © Vision & Control GmbH 2021 999.995.400.10-en-1.3...
  • Page 14: Technical Data

    SLF-100-W5K7-P-24V Technical Data 5 TECHNICAL DATA 5.1 General Parameters Parameter Characteristic Housing material Aluminium, black anodised Optical material Polycarbonate frosted Housing dimensions 54 mm x 32 mm x 21.5 mm (without connector) Dimensions light-emitting Diameter: 24 mm surface Filter thread M28 x 0.5 / depth 4.5 mm...
  • Page 15: Electrical Parameters

    SLF-100-W5K7-P-24V Technical Data 5.2 Electrical Parameters Parameter Operating voltage U 19 V 24 V 29 V Power consumption at U = 24 V DC 2.5 W 3.0 W 3.5 W Switch input Input voltage OFF 2.0 V ON/OFF Input current OFF 0 mA 0.2 mA...
  • Page 16: Conditions For Operation, Storage And Transport

    SLF-100-W5K7-P-24V Technical Data Spectral Emission Wavelength [nm] Image 2: Spectral emission 5.4 Conditions for Operation, Storage and Transport Observe the specified ambient conditions when transporting and storing the device. For accessories, connected devices and components observe the specific information in the associated instructions for use.
  • Page 17: Technical Drawings

    SLF-100-W5K7-P-24V Technical Data 5.5 Technical Drawings Image 3: Technical drawings (dimensions in mm) © Vision & Control GmbH 2021 999.995.400.10-en-1.3...
  • Page 18: Commissioning

    SLF-100-W5K7-P-24V Commissioning 6 COMMISSIONING NOTICE Installation and connection operations may only be performed in the off and de-energised state. 6.1 Unpacking 1. Lift the cardboard, together with the device, out of the carton. 2. Fold out the tucked in sides on the bottom of the cardboard. The film loosens and forms an insertion pocket.
  • Page 19: Connecting

    SLF-100-W5K7-P-24V Commissioning 6.3 Connecting NOTICE Cable damage • Comply with the specified minimum bending radius. • Cables must generally be mounted with a strain relief clamp. • Use cables corresponding to the specification (see data sheet). 6.3.1 Pin assignment Use the M8 connector to connect the device according to the pin assignment.
  • Page 20: Operation

    SLF-100-W5K7-P-24V Operation 7 OPERATION WARNING Possibly hazardous optical radiation emitted from this product • May be harmful to the eye. • In case of operation do not look into the lighting for a long time. CAUTION Physiological effects by flashing lights •...
  • Page 21: Making Operational Readiness

    SLF-100-W5K7-P-24V Operation 7.1 Making Operational Readiness The device is switched on by applying the operating voltage. The device is switched off by disconnecting it from the operating voltage supply. 7.2 Operating Modes The integrated controller supports the following operating modes: •...
  • Page 22 SLF-100-W5K7-P-24V Operation Switching behaviour Switching operation Continuous operation Shutter Lighting Switching signal Exposure time of the camera Delay time Power-on time Delay time 50 µs 100 µs 150 µs Power-on time 100 µs ∞ 999.995.400.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 23: Maintenance And Service

    SLF-100-W5K7-P-24V Maintenance and Service 8 MAINTENANCE AND SERVICE 8.1 Maintenance The device is maintenance-free. Depending on the operating environment, it may have to be cleaned. The housing can be cleaned according to the conditions applicable to the given protection class.
  • Page 24: Service

    SLF-100-W5K7-P-24V Maintenance and Service 8.2 Service Technical Support Please contact our technical support if you have any technical questions concerning our products. We will be glad to be of service: Monday to Thursday 8:00 to 17:00, and Friday 8:00 to 15:00.
  • Page 25: Disposal

    SLF-100-W5K7-P-24V Disposal 9 DISPOSAL The device and its accessories and packaging must be sent to environmentally compatible recycling. Do not throw electrical devices or tools into the household waste! According to European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in national law, unusable electric tools must be collected separately, and sent to environmentally compatible recycling.
  • Page 26: Eu Declaration Of Conformity

    D-98527 Suhl, Germany Representative: Dr. Jürgen Geffe, Managing director We, Vision & Control GmbH Suhl, declare that the product described below – Designation: SLF-100-W5K7-P-24V – Order no.: 1-33-346 has been manufactured in accordance with the following standards and normative documents: •...
  • Page 27 SLF-100-W5K7-P-24V © Vision & Control GmbH 2021 999.995.400.10-en-1.3...