Vision & Control SLE-150-B460-P-SL Instructions For Use Manual

Compact spot light, luminous colour: blue - 460 nm

Advertisement

Quick Links

creating machine vision
Instructions for Use
Instructions for Use
SLE-150-B460-P-SL
SLE-150-B460-P-SL
Compact spot light,
Compact spot light,
Luminous colour: Blue - 460 nm
Luminous colour: Blue - 460 nm
999.995.377.10-en-1.3
© Vision & Control GmbH 2021
VISION & CONTROL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLE-150-B460-P-SL and is the answer not in the manual?

Questions and answers

Summary of Contents for Vision & Control SLE-150-B460-P-SL

  • Page 1 VISION & CONTROL Instructions for Use Instructions for Use SLE-150-B460-P-SL SLE-150-B460-P-SL Compact spot light, Compact spot light, Luminous colour: Blue - 460 nm Luminous colour: Blue - 460 nm 999.995.377.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 2 Impress Publisher / Manufacturer Vision & Control GmbH Mittelbergstraße 16 98527 Suhl, Germany Telephone: +49 (0) 3681 7974-0 Telefax: +49 (0) 3681 7974-33 www.vision-control.com Name of the document 999.995.377.10-en-1.3 Date of first issue 2020-11-18 Date modified 2021-01-18 Copyright © Vision & Control GmbH 2021 Copyright It is forbidden to pass this document on to third parties, reproduce and communicate its contents in as far as this has not been expressly authorized.
  • Page 3 Validity These instructions for use are valid for the following device: Device Order no. SLE-150-B460-P-SL 1-33-300 Product Identification Designation Description Compact spot light - Attachment optics with condenser lens - High energy efficiency Luminous field diameter in mm at 200 mm Working distance...
  • Page 4: Table Of Contents

    SLE-150-B460-P-SL Table of Contents TABLE OF CONTENTS 1 Information about the Instructions of Use..........6 1.1 Intended Use....................6 1.2 Improper Use....................7 1.3 Qualified Personnel..................7 1.4 Warranty and Liability...................8 2 Safety......................9 2.1 Presentation of Safety Instructions.............. 9 2.2 Safe Handling of the Device..............10 3 Scope of Delivery and Accessories............
  • Page 5 SLE-150-B460-P-SL Table of Contents 8.1 Maintenance....................28 8.2 Service......................29 9 Disposal......................30 10 EU Declaration of Conformity..............31 © Vision & Control GmbH 2021 999.995.377.10-en-1.3...
  • Page 6: Information About The Instructions Of Use

    SLE-150-B460-P-SL Information about the Instructions of Use 1 INFORMATION ABOUT THE INSTRUCTIONS OF This document contains technical information, important instructions for correct installation, commissioning and use, as well as product information which were up-to-date at the time of going to press.
  • Page 7: Improper Use

    SLE-150-B460-P-SL Information about the Instructions of Use 1.2 Improper Use All unintended use and all device-related activities not described in these instructions of use is to be deemed as unauthorised misuse outside the legal limits of indemnity of the manufacturer.
  • Page 8: Warranty And Liability

    SLE-150-B460-P-SL Information about the Instructions of Use 1.4 Warranty and Liability The contents of this document have been checked carefully and correspond to current legislation and best practise at the time of going to press. However, the manufacturer shall not be liable for any damage arising from the use of this edition of the manual, and rejects any warranty derived therefrom.
  • Page 9: Safety

    SLE-150-B460-P-SL Safety 2 SAFETY 2.1 Presentation of Safety Instructions Each safety instruction is introduced by a key word and colour highlighted. The key word indicates the degree of danger. The danger and its cause are described, and then the measures to prevent conceivable consequences of the danger.
  • Page 10: Safe Handling Of The Device

    SLE-150-B460-P-SL Safety 2.2 Safe Handling of the Device Read the following applicable safety instructions carefully and completely. Follow the instructions for your own safety, the safety of other people, and to avoid damage to the device and the connected technical equipment. Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual.
  • Page 11: Scope Of Delivery And Accessories

    Because of the many possible configurations, the cables are listed in the accessories rather than included in the scope of delivery. 3.1 Scope of Delivery Designation Quantity Device SLE-150-B460-P-SL Instructions for Use SLE-150-B460-P-SL 3.2 Accessories vicolux smart light lighting controller Designation Description Order no.
  • Page 12 SLE-150-B460-P-SL Scope of Delivery and Accessories Connection cable DLC - operating voltage Designation Description Order no. Cable DLC3005 - 1.0 m to connect the DLC3005 to a current 1-30-222 source, PTSM 0.5/2-P-2.5 to cable Cable DLC3005 - 2.0 m 1-30-223 open end, 2x0.5 mm²...
  • Page 13 SLE-150-B460-P-SL Scope of Delivery and Accessories M8 4-pin connection cable, angled plug, 4A, 60V Designation Description Order no. Connection cable Connection cable with 4-pin M8 socket 1-11-605 M8-4pin, 2m and open cable end with ferrules, 4 x 0.25 mm², 4A, 60V, PUR, IP67,...
  • Page 14: Device Description

    SLE-150-B460-P-SL Device Description 4 DEVICE DESCRIPTION 4.1 Device Views Image 1: Device view Casing Light-emitting surface Filter thread M28x0.5 - depth: 5 mm Mounting hole M3x0.5 - depth: 4.5 mm Mounting hole Ø4.2 - through bore Connector M8-4pin 999.995.377.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 15: Notices On The Device

    SLE-150-B460-P-SL Device Description 4.2 Notices on the device Following instructions are provided on the device: SLX-XXX-XXXX-P-SL Made in Germany www.vision-control.com Notes on power supply Device designation as DataMatrix code Device designation as plain text Manufacturer information © Vision & Control GmbH 2021...
  • Page 16: Technical Data

    SLE-150-B460-P-SL Technical Data 5 TECHNICAL DATA 5.1 General Parameters Parameter Characteristic Housing material Aluminium, black anodised Optical material Glass Housing dimensions 54 mm x 32 mm x 30 mm (without connector) Dimensions light-emitting Diameter: 24 mm surface Connector Male connector, M8, 4-pin Weight 68.5 g...
  • Page 17: Electrical Parameters

    SLE-150-B460-P-SL Technical Data 5.2 Electrical Parameters NOTICE If the lighting is operated by using power sources of other manufacturers, verify that temperature, current and pulse time have to be kept inside specified limits! There is no automatic limitation of the electrical parameters. The LED overheating protection is not guaranteed.
  • Page 18: Photometric Parameters

    SLE-150-B460-P-SL Technical Data 5.3 Photometric Parameters Parameter Beam angle 40° Luminous field diameter 150 mm Peak wavelength λ 455 nm peak Dominant Wavelength λ 444 nm 459 nm 465 nm Spectral bandwidth Δλ 27 nm Luminous efficacy of radiation 51.0 lm/W...
  • Page 19: Conditions For Operation, Storage And Transport

    SLE-150-B460-P-SL Technical Data Spectral Emission Wavelength [nm] Image 2: Spectral emission 5.4 Conditions for Operation, Storage and Transport Observe the specified ambient conditions when transporting and storing the device. For accessories, connected devices and components observe the specific information in the associated instructions for use.
  • Page 20: Technical Drawings

    SLE-150-B460-P-SL Technical Data 5.5 Technical Drawings Image 3: Technical drawings (dimensions in mm) 999.995.377.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 21: Commissioning

    SLE-150-B460-P-SL Commissioning 6 COMMISSIONING NOTICE Installation and connection operations may only be performed in the off and de-energised state. 6.1 Unpacking 1. Lift the cardboard, together with the device, out of the carton. 2. Fold out the tucked in sides on the bottom of the cardboard. The film loosens and forms an insertion pocket.
  • Page 22: Mounting The Device

    SLE-150-B460-P-SL Commissioning 6.2 Mounting the Device The following bores can be used for assembly. Image 4: Mounting holes 6 x M3x0,5 tapped hole maximum screwed-in depth: 4.5 mm 2 x Ø4.2 mounting hole (through bore) 999.995.377.10-en-1.3 © Vision & Control GmbH 2021...
  • Page 23: Connecting

    SLE-150-B460-P-SL Commissioning 6.3 Connecting NOTICE Cable damage • Comply with the specified minimum bending radius. • Cables must generally be mounted with a strain relief clamp. • Use cables corresponding to the specification (see data sheet). 6.3.1 Connecting to vicolux smart light lighting controller...
  • Page 24: Pin Assignment

    SLE-150-B460-P-SL Commissioning 6.3.2 Pin assignment Use the M8 connector to connect the device according to the pin assignment. Pin assignment Connection diagram +ILED ® vicolux smart light -ILED Image 6: Connection diagram vicolux smart Image 5: M8 connector, 4-pin light...
  • Page 25: Operation

    SLE-150-B460-P-SL Operation 7 OPERATION CAUTION Physiological effects by flashing lights • Working under flashing lights can cause effects such as headache, nausea, or epileptic seizures. • Avoid exposure to certain kinds of flashing lights or stroboscopes. • Wear protective goggles.
  • Page 26: Making Operational Readiness

    SLE-150-B460-P-SL Operation 7.1 Making Operational Readiness NOTICE This device is intended for use with suitable controllers only. All technical data and permissible conditions must be complied with. The lighting is switched on by turning on the LED current I The lighting is switched off by turning off the LED current I 7.2 Operation with vicolux smart light lighting controller...
  • Page 27: Operating Modes

    SLE-150-B460-P-SL Operation 7.3 Operating Modes Continuous operation Apply a constant current I to the lighting. Flash operation Apply current pulses I to the lighting. Observe the specified parameters. see "Electrical Parameters", page 17 © Vision & Control GmbH 2021 999.995.377.10-en-1.3...
  • Page 28: Maintenance And Service

    SLE-150-B460-P-SL Maintenance and Service 8 MAINTENANCE AND SERVICE 8.1 Maintenance The device is maintenance-free. Depending on the operating environment, it may have to be cleaned. The housing can be cleaned according to the conditions applicable to the given protection class.
  • Page 29: Service

    SLE-150-B460-P-SL Maintenance and Service 8.2 Service Technical Support Please contact our technical support if you have any technical questions concerning our products. We will be glad to be of service: Monday to Thursday 8:00 to 17:00, and Friday 8:00 to 15:00.
  • Page 30: Disposal

    SLE-150-B460-P-SL Disposal 9 DISPOSAL The device and its accessories and packaging must be sent to environmentally compatible recycling. Do not throw electrical devices or tools into the household waste! According to European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in national law, unusable electric tools must be collected separately, and sent to environmentally compatible recycling.
  • Page 31: Eu Declaration Of Conformity

    D-98527 Suhl, Germany Representative: Dr. Jürgen Geffe, Managing director We, Vision & Control GmbH Suhl, declare that the product described below – Designation: SLE-150-B460-P-SL – Order no.: 1-33-300 has been manufactured in accordance with the following standards and normative documents: •...
  • Page 32 Vision & Control GmbH Mittelbergstraße 16 98527 Suhl, Germany Telephone +49 (0) 3681 7974-0 Telefax: +49 (0) 3681 7974-33 Vision & Control GmbH...

Table of Contents