Page 3
Validity These instructions for use are valid for the following device: Device Order no. SLE-150-B460-P-SL 1-33-300 Product Identification Designation Description Compact spot light - Attachment optics with condenser lens - High energy efficiency Luminous field diameter in mm at 200 mm Working distance...
SLE-150-B460-P-SL Table of Contents TABLE OF CONTENTS 1 Information about the Instructions of Use..........6 1.1 Intended Use....................6 1.2 Improper Use....................7 1.3 Qualified Personnel..................7 1.4 Warranty and Liability...................8 2 Safety......................9 2.1 Presentation of Safety Instructions.............. 9 2.2 Safe Handling of the Device..............10 3 Scope of Delivery and Accessories............
SLE-150-B460-P-SL Information about the Instructions of Use 1 INFORMATION ABOUT THE INSTRUCTIONS OF This document contains technical information, important instructions for correct installation, commissioning and use, as well as product information which were up-to-date at the time of going to press.
SLE-150-B460-P-SL Information about the Instructions of Use 1.2 Improper Use All unintended use and all device-related activities not described in these instructions of use is to be deemed as unauthorised misuse outside the legal limits of indemnity of the manufacturer.
SLE-150-B460-P-SL Information about the Instructions of Use 1.4 Warranty and Liability The contents of this document have been checked carefully and correspond to current legislation and best practise at the time of going to press. However, the manufacturer shall not be liable for any damage arising from the use of this edition of the manual, and rejects any warranty derived therefrom.
SLE-150-B460-P-SL Safety 2 SAFETY 2.1 Presentation of Safety Instructions Each safety instruction is introduced by a key word and colour highlighted. The key word indicates the degree of danger. The danger and its cause are described, and then the measures to prevent conceivable consequences of the danger.
SLE-150-B460-P-SL Safety 2.2 Safe Handling of the Device Read the following applicable safety instructions carefully and completely. Follow the instructions for your own safety, the safety of other people, and to avoid damage to the device and the connected technical equipment. Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual.
Because of the many possible configurations, the cables are listed in the accessories rather than included in the scope of delivery. 3.1 Scope of Delivery Designation Quantity Device SLE-150-B460-P-SL Instructions for Use SLE-150-B460-P-SL 3.2 Accessories vicolux smart light lighting controller Designation Description Order no.
Page 12
SLE-150-B460-P-SL Scope of Delivery and Accessories Connection cable DLC - operating voltage Designation Description Order no. Cable DLC3005 - 1.0 m to connect the DLC3005 to a current 1-30-222 source, PTSM 0.5/2-P-2.5 to cable Cable DLC3005 - 2.0 m 1-30-223 open end, 2x0.5 mm²...
Page 13
SLE-150-B460-P-SL Scope of Delivery and Accessories M8 4-pin connection cable, angled plug, 4A, 60V Designation Description Order no. Connection cable Connection cable with 4-pin M8 socket 1-11-605 M8-4pin, 2m and open cable end with ferrules, 4 x 0.25 mm², 4A, 60V, PUR, IP67,...
SLE-150-B460-P-SL Technical Data 5 TECHNICAL DATA 5.1 General Parameters Parameter Characteristic Housing material Aluminium, black anodised Optical material Glass Housing dimensions 54 mm x 32 mm x 30 mm (without connector) Dimensions light-emitting Diameter: 24 mm surface Connector Male connector, M8, 4-pin Weight 68.5 g...
SLE-150-B460-P-SL Technical Data 5.2 Electrical Parameters NOTICE If the lighting is operated by using power sources of other manufacturers, verify that temperature, current and pulse time have to be kept inside specified limits! There is no automatic limitation of the electrical parameters. The LED overheating protection is not guaranteed.
SLE-150-B460-P-SL Technical Data Spectral Emission Wavelength [nm] Image 2: Spectral emission 5.4 Conditions for Operation, Storage and Transport Observe the specified ambient conditions when transporting and storing the device. For accessories, connected devices and components observe the specific information in the associated instructions for use.
SLE-150-B460-P-SL Commissioning 6 COMMISSIONING NOTICE Installation and connection operations may only be performed in the off and de-energised state. 6.1 Unpacking 1. Lift the cardboard, together with the device, out of the carton. 2. Fold out the tucked in sides on the bottom of the cardboard. The film loosens and forms an insertion pocket.
SLE-150-B460-P-SL Commissioning 6.3 Connecting NOTICE Cable damage • Comply with the specified minimum bending radius. • Cables must generally be mounted with a strain relief clamp. • Use cables corresponding to the specification (see data sheet). 6.3.1 Connecting to vicolux smart light lighting controller...
SLE-150-B460-P-SL Operation 7 OPERATION CAUTION Physiological effects by flashing lights • Working under flashing lights can cause effects such as headache, nausea, or epileptic seizures. • Avoid exposure to certain kinds of flashing lights or stroboscopes. • Wear protective goggles.
SLE-150-B460-P-SL Operation 7.1 Making Operational Readiness NOTICE This device is intended for use with suitable controllers only. All technical data and permissible conditions must be complied with. The lighting is switched on by turning on the LED current I The lighting is switched off by turning off the LED current I 7.2 Operation with vicolux smart light lighting controller...
SLE-150-B460-P-SL Maintenance and Service 8 MAINTENANCE AND SERVICE 8.1 Maintenance The device is maintenance-free. Depending on the operating environment, it may have to be cleaned. The housing can be cleaned according to the conditions applicable to the given protection class.
SLE-150-B460-P-SL Maintenance and Service 8.2 Service Technical Support Please contact our technical support if you have any technical questions concerning our products. We will be glad to be of service: Monday to Thursday 8:00 to 17:00, and Friday 8:00 to 15:00.
SLE-150-B460-P-SL Disposal 9 DISPOSAL The device and its accessories and packaging must be sent to environmentally compatible recycling. Do not throw electrical devices or tools into the household waste! According to European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in national law, unusable electric tools must be collected separately, and sent to environmentally compatible recycling.
D-98527 Suhl, Germany Representative: Dr. Jürgen Geffe, Managing director We, Vision & Control GmbH Suhl, declare that the product described below – Designation: SLE-150-B460-P-SL – Order no.: 1-33-300 has been manufactured in accordance with the following standards and normative documents: •...