  • Page 1 Downward Flow Cartridge Dust Collector Owner’s Manual Model SFC...
  • Page 2 Your SFC system should provide many years of trouble-free service. This manual will help you understand the operation of your SFC unit. It will also help you understand how to maintain it in order to achieve top performance. For quick future reference, fill in the system and filter information in the spaces below.
  • Page 3: Table Of Contents

    Page Safety Precautions ....................iii 1. Important Notice ....................1 2. Introduction ......................1 2.1 Unit Nomenclature ..................1 2.2 Description and Operation ................1 2.3 Air Filtering Operation ..................2 2.4 Filter Cleaning Cycle ..................2 3. Installation ......................3 3.1 Off Loading and Inspection ................3 3.2 Installation Planning..................3 3.3 Assembly of Standard Equipment ..............3 3.3.1 Hopper Assemblies ................6 3.3.2 Fully Assembled Filter Module Sections ............6...
  • Page 4 5.6 Servicing Optional Return Air Safety Filters (HEPA/ASHRAE) ......25 5.7 ProTura Nanofiber Cartridge Filters .............26 ® 5.8 Explosion Vent Replacement ................26 5.8.1 Dome Style Explosion Vent Replacement ..........26 6. Troubleshooting Guide ..................27 7. Illustrated Parts ....................30 SFC Series Bill of Materials ................31 Warranty Policy ....................32...
  • Page 5: Safety Precautions

    SAFETY PRECAUTIONS We have provided many important safety messages in this manual and on your SFC dust collector. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”...
  • Page 6 DustHog dust collector models such as the MCB, SDC, and SFC. The buyer or owner/user is responsible to supply, install and test the sprinkler head and any related or required fire control system devices, components or accessories.
  • Page 7 Page intentionally left blank...
  • Page 8: Important Notice

    • Avoid mixing combustible materials such as alumi- num, paper, wood or other organic dusts with dusts The SFC dust collector should not be used for any purpose not generated from grinding materials. A fire hazard could listed in this manual.
  • Page 9: Air Filtering Operation

    This pulsing action dislodges the collected particles from the media, where they fall into the hopper and are discharged to a dust stor- age drum or drawer. 44-10334-0001 FIGURE 1 SFC Air Filter Operation & Cleaning...
  • Page 10: Installation

    These sible internal damage. Notify your delivery carrier and enter a claim dampers can be installed on the inlet or outlet ducting of the SFC if any damage is found.
  • Page 13: Hopper Assemblies

    3.3.1 Hopper Assemblies 3.3.2 Fully Assembled Filter Module Sections The SFC Series filter module is designed to mount directly on Apply two ribbons of sealant to hopper flange to create “figure 8” pattern around mounting holes. Refer to Figure 7, Detail A.
  • Page 18: Electrical Installation

    (25’ [7.5 meters] provided by Parker) to the panel fittings ened. Remove lift slings and spreader bars and clear all tools and the SFC unit. Connect the dirty air plenum of the SFC to from the work area. the high pressure port (dirty air) on the panel as shown in Figure NOTE: Make certain all bolts (including the anchor bolts) are 8.
  • Page 22: Heater Wiring

    Distance of Supply Air Pipe Diameter Section Piping Run From Main Outlet ducting from the SFC unit to the blower package can be con- Modules Compressor Line nected to either the top or bottom clean air section access panel(s). It is recommended industry practice to provide vibration isolation...
  • Page 25: Duct Silencer Installation

    The abrasive inlet is designed to use the front access panel(s) of Drum Lid Installation the SFC Series modules as the inlet area to the unit. There are two styles available – a single or dual module abrasive inlet. Each is...
  • Page 26: Inlet Cover And Blank Cover Plate Installation

    3.6.6 Inlet Cover and Blank Cover Plate Installation mechanism to secure the drum lid and drum. To install the clamp: Inlet collar and blank cover plates bolt directly to the SFC unit. Inlet Before placing the drum lid into place, open the clamp and slide it and outlet collar assemblies are specified with initial order;...
  • Page 27 FIGURE 15 EDAP Installation 48-10007 FIGURE 16 EDAP Interconnection...
  • Page 28: Operation

    3.6.9 Extended Dirty Air Plenum (EDAP) For 5 High SFC Unit 3.6.8 Explosion Vent installation The normal shipping routine for an assembled SFC unit is with an 3.6.8.1 Introduction enclosed box truck. This type of truck will not be able to transport an assembled 5-high unit due to height restrictions within the Your Parker Dust-Hog®...
  • Page 29: Start-Up

    4.1 Start-Up Inspect the installation area and make certain no tools, parts, etc., have been left on or inside the SFC unit. Check blower discharge to make certain it is free from all debris. Start motor/blower and check for proper rotation. A rotation arrow is located on the blower housing.
  • Page 31: Checklist

    Nanofiber filters are the only replacement filters which pro- ® PS” switch on the timerboard to PS position. The MOT AUX vide the highest level of performance expected from the SFC Dust terminals at the timerboard should be field wired for the Collector.
  • Page 32: Dust Removal

    Disconnect electrical power before install- 7. The SFC dust collector is now ready to be placed back in service. ing or servicing any electrical component. Reconnect electrical power and air supply. Please follow the ini- tial start-up checklist to ensure proper unit performance.
  • Page 33: Servicing Cartridge Media

    Periodically check the pressure drop across the return air safety fil- ters. Replace when the differential pressure drop exceeds 2” w.g. (51 mmAq) for ASHRAE filters and 3” w.g. (76 mmAq) for HEPA filters. GENERAL DESCRIPTION CARTRIDGE FILTER PARKER PART NUMBER OF FILTER MEDIA ProTura Nanofiber 33-10089...
  • Page 34: Protura ® Nanofiber Cartridge Filters

    5.7 ProTura Nanofiber Cartridge Filters ® 6. Troubleshooting Guide The SFC product line is designed to accept ProTura Nanofiber ® Use the troubleshooting guide to correct any problems that cartridge filters. Table 2 highlights the most common Parker occur with your dust collection unit. If the problem or condition cartridge filters.
  • Page 35 PROBLEM POSSIBLE CAUSES RECOMMENDED SOLUTIONS Motor/blower won’t start or won’t stay Blower rotation is running in reverse. Reverse blower rotation (refer to Section running. 5.1). No voltage to system. Check primary voltage to motor circuits for proper voltage on all legs. Improper electrical wiring.
  • Page 36 ProTura ® Filters are at the end of their service life. Nanofiber cartridge filters from Parker. Each cartridge filter has a filter part number affixed to end cap (refer to Table 2 for the ProTura ® Nanofiber cartridge filters).
  • Page 37: Illustrated Parts

    7. Illustrated Parts 44-10330-0001 FIGURE 21 SFC Series FIGURE 22 SFC Series Explosion Vents...
  • Page 38 SFC Dust Collector Bill of Materials Item Part No. Description Filter (Consult Parker) 02-10019-0001 QuickSeal Filter Access Door Assembly 02-10019-0002 High Temp QuickSeal Filter Access Door Assembly 02-10019-0003 QuickSeal Filter Access Door Assembly, Exp Type 42-10002-0001 External Filter Door Seal Gasket...
  • Page 39 Page intentionally left blank...
  • Page 40 1. Subject to the terms and conditions hereof, Parker-Hannifin Corporation (PARKER) warrants that major structural components on MCB, PNP, SDC, SFC, and SHM series will be free from defects in materials and workmanship for ten (10) years from the date of shipment from Parker. Subject to the terms and conditions hereof, warrants to the original...
  • Page 41 On claims that require repaired parts return, the claim will be processed after the part has been evaluated by the Parker IGFG Quality Department for verification of failure mode. The claims will be paid in the form of a credit to the customer’s account.
  • Page 42 310 637 3400 +44 (0) 191 410 5121 +27 11 9610700 www.parker.com/watermakers www.parker.com/processfiltration www.parker.com/africa © 2020 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies IOM_PKE_SFC_122020_Adam PN: 44-10300-0001 Parker Hannifin Corporation Industrial Gas Filtration and Generation Division...