Info And Statistic Parameters; User Commands; Alarm Values - gefran WPA-F User Manual

Contactless magnetostrictive linear position transducer
Table of Contents

Advertisement

● Sensor status: no parameters
● All Positions: no parameters
● All Velocities: no parameters
The device WPA-F/WRA-F provides a list of parameters which is possible to readout in order to receive some information and useful
statistic data from the device.
Index (dec)
DataFormat
3073
Unsigned32
3075
Int16
3076
Int16
4096
Unsigned32
4097
Unsigned32
4098
Unsigned32
4099
Unsigned32
Explanation:
● Operating time counter: the working time of the device is stored in non volatile memory since first power on or since last reset
command (see par 4.5); this increasing counter has resolution 0,1h (6 min)
● Temperature: it's the temperature measured internally by electronics, with 0,1°C resolution; this value is volatile
● Temperature Max: it's the maximum temperature measured internally by electronics, with 0,1°C resolution, stored in non vol-
atile memory, since first power on or since last reset command (see par 4.5)
● Nominal Span: it's the full range stroke of the device as defined in the ordering code, with 1um resolution
● Serial Number: it's the Serial Number as reported on device nameplate
● Calibration Date: it reports the date of calibration of device in the coding YYYYMMDD
● SensorSWVersion: SW version of the processor managing the measure
The device WPA-F/WRA-F provides a list of commands which the user can act in case of
Index (dec) DataFormat
6144
Unsigned8
6145
Unsigned8
Explanation:
● ResetUserStatisticsData: through this command the user can request the reset of following statistics data:
- OperatingTimeCounter
- TemperatureMax
● StoreStatisticsData: through this command the user can force an immediate storage of statistics parameters (OperatingTime-
Counter and TemperatureMax), otherwise the auto saving happens every 6 min
In case of Diagnostics events the WPA-F / WRA-F communicates through Profinet alarm messages the following:
Alarm ID
Meaning
16
Parameterization Error
17
Supply Voltage Error
27
Number of cursors Error
5
Temperature Error
19
Internal Communication Error
Explanation:
● Parameterization Error: the device received an uncorrect parameterization
● Supply Voltage Error: the error rises according to the configuration of parameter "Voltage Supply Alarm"
● Number of cursors Error: the error rises according to the configuration of parameter "Number of Cursors Alarm"
● Temperature Error: the error rises if Electronics temperature overtakes the working temperature limit
● Internal Communication Error: the error rises if a failure in internal communication between processors happens
80715_MAN_WPA-F_WRA-F_03-2021_ENG

4.4. Info and statistic parameters

Name
OperatingTimeCounter
Temperature
TemperatureMax
NominalSpan
SerialNumber
CalibrationDate
SensorSwVersion

4.5. User commands

Name
ResetUserStatisticsData
StoreStatisticsDat

4.6. Alarm values

Access
UM
RO
[0,1h]
RO
[0,1°C]
RO
[0,1°C]
RO
[um]
RO
RO
RO
Access
Data to Write
WO
1
WO
1
Range/Format
0...4000000
YYWWNNNN
YYYYMMDD
YYYYMMDD
9