Unknown BIOS error. Error
code = 004Ah
Unknown BIOS error. Error
code = 004Bh
Floppy Controller Failure
USB eModule Error Messages
Message Displayed
Warning! Unsupported USB
device found and disabled!
Warning! Port 60h/64h
emulation is not supported
by this USB Host Controller!
Warning! EHCI controller
disabled. It requires 64bit
data support in the BIOS.
SMBIOS eModule Error Messages
Message Displayed
Not enough space in Runtime
area!!. SMBIOS data will not be
available.
CPU eModule Error Messages
Message Displayed
Warning! This system board does not support the power
requirements of the installed processor. The processor
will be run at a reduced frequency, which will impact
system performance. area!!. SMBIOS data will not be
available.
password verification.
This message is displayed when ADM module is not present in
the AMIBIOS8 ROM.
This message is displayed when language module is not
present in the AMIBIOS8 ROM.
Error in initializing legacy Floppy Controller.
This message is displayed when a non-bootable USB device is
enumerated and disabled by the BIOS.
This message is displayed to indicate that port 60h/64h
emulation mode cannot be enabled for this USB host
controller. This condition occurs if USB KBC emulation option
is set for non-SMI mode.
This message is displayed to indicate that EHCI controller is
disabled because of incorrect data structure. This condition
occur if the USB host controller needs 64-bit data structure
while the USB is ported with 32-bit data structure.
This message is displayed when the size of the
SMBIOS data exceeds the available SMBIOS runtime
storage size
Description
Description
Description
This message is displayed when
the power requirements of the
board do not match the power
requirement of the CPU.