Page 1
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. CROWN FOOD SERVICE EQUIPMENT A Middleby Company 70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 Telephone: 919-762-1000 www.crownsteamgroup.com...
Gas Fired Steamers PECIFICATIONS SAFETY PRECAUTIONS Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions. The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
Gas Fired Steamers Table of Contents RETAIN THIS MANUAL FOR FUTURE REFERENCE. Table of Contents Important Notes For Installation and Operation ..............2 Service Connections ......................4 Installation Instructions ......................7 Performance Check ......................9 Operation ..........................10 Maintenance ......................... 13 Cooking Guidelines .......................
Factor ....... 6.8 - 7.3 Silica ........Less than 13 PPM Water which does not meet these standards should be treated with the installation of Middleby’s Water Treatment System. Call 919-762-1000 if you have questions concerning your water meeting these parameters.
Page 5
Gas Fired Steamers NSTALLATION NSTALLATION NSTRUCTIONS NPACKING IMMEDIATELY INSPECT FOR SHIPPING DAMAGE Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. Prior to installation, verify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel.
Page 6
Gas Fired Steamers NSTALLATION Clearances Adequate clearance must be provided in aisle and at the side and back. Adequate clearances for air openings into the combustion chamber must be provided, as well as for serviceability for use on noncombustible floors. Minimum clearance from combustible and noncombustible construction, 0”...
Gas Fired Steamers NSTALLATION Gas Connections CAUTION The pipe thread compound used when installing pipes must be a type that is resistant to the action of liquified petroleum or propane gases. NOTICE If this equipment is being installed at over 2,000 feet altitude and was not so specified on order, contact service department.
Page 8
Gas Fired Steamers NSTALLATION Cold Water Condenser The steamer is equipped with a cold water condenser, in the rear of the cooking chamber, which helps to condense the steam prior to discharge into the drain. The steamer freely vents itself by the negative pressure created by the condensate water drainage.
Gas Fired Steamers Performance Check Performance Check CAUTION The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. Once the steamer is installed and all mechanical connections have been made, thoroughly test the steamer before operation.
Operation Gas Fired Steamers PERATION CAUTION If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected. Lighting NOTICE Do not attempt to operate this unit in the event of a power failure. 1.
Page 11
Gas Fired Steamers Operation WARNING When this appliance is installed with casters and is connected to the supply piping by means of a connector for moveable appliances, a restraint to prevent damage to the connector or quick disconnect device should have been installed.
Operation Gas Fired Steamers Shutdown STAND BY a. Set timer to “OFF” position and leave door slightly open. Complete Shutdown a. Set timer to “OFF” and turn power switch “OFF”. Steam generator will drain automatically. b. Turn water supply “OFF”. c.
Gas Fired Steamers Maintenance Maintenance NOTICE Contact the factory, the factory representative or local service company to perform maintenance and repairs. WARNING Disconnect the power supply to the appliance before cleaning or servicing. CAUTION The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. CAUTION Live steam and accumulated hot water in the compartment may be released when the door is opened.
Page 14
Maintenance Gas Fired Steamers Weekly (or more often if necessary): 1. Clean exterior with a damp cloth and polish with a soft dry cloth. 2. Use a non-abrasive cleaner to remove discolorations. 3. Clean around burner air mixer and orifice if lint has accumulated. It is NOT RECOMMENDED to use cleaning agents that are corrosive.
Page 15
Gas Fired Steamers Deliming Procedure Deliming Procedure CAUTION Read and follow instructions on the CLR bottle. Use plastic or rubber gloves to avoid skin contact. If CLR comes in contact with skin, rinse with clean water. 1. Completely drain steam generator by setting on/off switch to “OFF”. Set cooking timer to 0. 2.
Gas Fired Steamers ROUBLESHOOTING ROUBLESHOOTING Burners No Not Come On 1. Gas supply to unit is “OFF”. 2. Power Switch is not turned “ON”. 3. Steam generator probe not sensing the water level, will not call for ignition. 4. Ignitor not functioning. 5.
Page 20
When service is needed, contact a Crown Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance. CROWN FOOD SERVICE EQUIPMENT A Middleby Company 70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 Telephone: 919-762-1000 www.crownsteamgroup.com...
Need help?
Do you have a question about the CROWN GSX-7HE and is the answer not in the manual?
Questions and answers