CS-C18DKV CU-C18DKV / CS-C24DKV CU-C24DKV
2.2.

Indoor Unit

AUTO
OFF / ON
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode.Use when the remote
control cannot be used.
• Press for > 5 second to operate Cooling
operation mode and compressor force
to on ("beep" sound will be heard). Used
when test running or servicing.
• Within 20 second of Cooling operation,
press continuously for > 5 second to enter
various setting mode. "beep, beep" sound
will be heard. (Used to toggle remote
control signal receiving sound or select
remote control transmission code.)
Operation Indication Lamps (LED)
POWER
TIMER
QUIET
POWERFUL
• ION (Green) ........... Lights up in Ionizer
• SUPER
ALLERU-BUSTER (Blue) ... Lights up in operation.
Operation Mode
• Cooling, Soft Dry and Automatic Operation.
Timer Operation
• Delay OFF/ON Timer control.
Powerful Operation
• Reaches the desired room temperature
quickly.
(Green) ........ Lights up in operation,
blinks in Automatic
Operation judging.
(Orange) ....... Lights up in Timer
Setting.
(Orange) ........ Lights up in Quiet
Operation.
(Orange) .. Lights up in Powerful
Operation.
Operation.
Quiet Operation
• To provide quiet operation.
Random Auto Restart Control
• Unit will be restarted, when resume from
power failure, at previous setting.
Anti-Freezing Control
• To prevent indoor heat exchanger from
freezing.
Ionizer Operation
• Generate and discharge negative ion.
Indoor Fan Speed Control
• Manual control fan speed
(High, Medium and Low).
• Automatic fan speed
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical and
horizontal airflow.
Time Delay Safety Control
• Restarting is inhibited for approximately
3 minutes.
7 Minutes Time Save Control
• To reduce the built up humidity inside
the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.