Serial Port 1 .................... [Disabled]
Base Address .................. [----]
IRQ ........................... [-]
Serial Port 2 .................... [Enabled]
Base Address .................. [3F8h]
IRQ ........................... [4]
Parallel Port .................... [Enabled]
Base Address .................. [378h]
IRQ ........................... [7]
Operation Mode ................ [EPP]
Floppy Disk Controller ........... [Enabled]
IDE Controller ................... [Both]
PS/2 Mouse Controller ............ [Enabled]
USB Host Controller .............. [Enabled]
USB Legacy Mode ................ [Enabled]
Onboard Audio Chip ............... [Enabled]
Game Port Address ................ [201]
MIDI Port Address ................ [330]
MIDI Port IRQ .................... [5]
Onboard Modem Chip ............... [Disabled]
Onboard Ethernet Chip ............ [Enabled]
NOTE: This screen can be seen on Acer Power Sxb model.
The following table describes the parameters found in this menu. Settings in boldface are the default and
suggested settings.
Parameter
Serial Port 1
Base Address
IRQ
Serial Port 2
Base Address
IRQ
Parallel Port
Base Address
IRQ
34
Onboard Peripherals
ECP DMA Channel ............. [-]
Description
Lets you enable or disable the serial port 1.
Lets you set a logical base address for each
serial port. This parameter is configurable only
if the Serial Port parameter is enabled.
Lets you assign an interrupt for each serial port.
This parameter is configurable only if the Serial
Port parameter is enabled.
Lets you enable or disable the serial port 2.
Lets you set a logical base address for each
serial port. This parameter is configurable only
if the Serial Port parameter is enabled.
Lets you assign an interrupt for each serial port.
This parameter is configurable only if the Serial
Port parameter is enabled.
Lets you enable or disable the parallel port.
Lets you set a logical base address for the
parallel port. This parameter is configurable
only if the Parallel Port parameter is enabled.
Lets you assign an interrupt for the parallel port.
This parameter is configurable only if the
Parallel Port parameter is enabled.
Options
Enabled or Disabled
Enabled or Disabled
3F8h, 3E8h, 2E8h
4 or 11
Enabled or Disabled
378h, 278h
5 or 7
Chapter 2