8.5.
After each cleaning operation, make sure that the filter on the end of the detergent pick-up pipe is
not clogged. If it is, remove it and rinse under running water (Fig 19).
8.6.
If dirt has deposited on the inside of the spray head assembly, remove the clear plastic cover (Fig
20), by unscrewing it, and rinse off with clean water. Refit when thoroughly dry.
8.7.
The air outlet filters should be replaced regularly; to remove the cover, insert a coin into the slot
and carefully prise the cover off. After replacing the filter, refit the cover, ensuring the arrow on the
inside is pointing upwards (Fig 21).
Fig 20

9. MAINTENANCE

 WARNING! Before doing any maintenance ALWAYS disconnect the power supply.
9. 1. After wet vacuum cleaning, empty the contents of the drum. Clean and dry the drum and accessories to avoid scaling.
9. 2. Periodically check to ensure that the machine and accessories are not blocked or damaged and are in good working order.
Damaged parts must be replaced. Blocked hoses or tubes will impair performance and may damage the machine.
Such damaged units returned for repair will not be accepted under warranty and may incur expensive repair bills.
Never use machine as a dry cleaner without the cloth filter. Dirt in the motor will cause failure and also invalidate warranty.
9. 3. Clean the dry cloth filter at regular intervals in a suitable container full of light soapy water (DO NOT use solvents).
Allow to dry before use. Check the filter condition and replace if necessary.

10. TROUBLESHOOTING

THE PROBLEM
Unit does not start.
Low suction.
Motor speed
increases.
Foam comes out of air
filter.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
THE CAUSE
No current. Power cable, switch, or motor
faulty. Tank may be full of water.
Container full.
Filter obstructed.
Outlet filter obstructed.
Hose or tool blocked.
Container full.
Filter obstructed.
Hose or tool blocked.
Wrong detergent used.
Used on carpet previously cleaned with
foaming detergent.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Fig 21
THE SOLUTION
Check the plug and fuse. Repair or replace faulty part. Empty
tank if full.
Empty container.
Clean or replace filter.
Clean or replace.
Check and remove obstruction.
Empty container.
Clean or replace filter.
Check and remove obstruction.
Use only SEALEY "VM" or SORMATOP.
Add SEALEY VMR922 anti-foaming agent to dirty water tank.