UAP100120CFB
1
2
ERROR CODE:
****
3a
BT
P 3
bar
P 3
bar
3b
b a r
/
p si
3 sec.
3c
b a r
/
p s i
3b
k N
/
l b f
3 sec.
3d
BT
F 74
lbf
F 369
lbf
Klauke i-press
www.klauke.com/connectivity
Klauke i-press
HE.16993_D © 11/2017
4a
4b
3 sec.
4c
Error code
*1
4d
*2
Bluetooth (if connected)
Battery charging level
Current pressure
Pressure max.
5
to change:
bar / psi
6
7
to change:
kN / lbf
Software
®
App
®
WORK
SERVICE
USER 3:
Doubleclick
RD3
Doppelklick
USER SELECT 3:
Singleclick
RD3
Einfachklick
enter menue
USER SELECT:
Doubelclick
RD3
Doppelklick
select
USER SELECT:
Doubelclick
RD3
Doppelklick
confi rmed
NEXT
SERVICE:
Cycles
9826 OP
s
(until next service)
Since manufacturing:
TOTAL:
t = 0
07
h
operating houres
.
Q = 21
12 Ah
.
Capacity
n = 174
# crimps
≤ 20 sec.
> 20 sec.
≤ 20 sec.
REPEAT
DON´T DO
*1
Error codes:
1 Overcurrent fuse
2 Overcurrent comparator
3 Overheat board
4 Overheat battery
5 Battery empty, operation stop
6 Faulty crimp
motor in operation
7 Faulty crimp
motor not in operation
8 Low battery
9 Battery empty
10 RTC battery low
11 Tool deactivated
12 Service necessary
13 RTC not found
14 BT unit not found
16 Pressure sensor not found
17 Burst pressure exceeded
18 Battery temperature too low
1 Überstrom durch
Überstromsicherung
2 Überstrom durch Komparator
3 Boardtemperatur zu hoch
4 Akkutemperatur zu hoch
5 Akkuspannung während der
Operation zu gering
6 Fehlpressung bei
laufendem Motor
7 Fehlpressung bei
stehendem Motor
8 Niedrige Akkuspannung
9 Akku leer
10 RTC-Batterie leer
11 Werkzeug deaktiviert
12 Service nötig
13 RTC nicht verfügbar
14 BT-Modul nicht verfügbar
16 Drucksensor nicht verfügbar
17 Berstdruck überschritten
18 Akkutemperatur zu gering
*2
(2Hz)
30% max.
General