Operating Instructions; Servicing - Mr. Heater MHC60FAV Operating Instructions And Owner's Manual

Forced air propane construction heater
Table of Contents

Advertisement

Available languages

Available languages

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION
1.
Check the heater for possible shipping damage. If any is
found, immediately notify the factory. (800-251-0001)
2.
Follow all of the "Precautions".
3.
Connect the POL fitting of hose and regulator assembly to the
propane cylinder by rotating the POL nut counterclockwise
into the propane cylinder's valve outlet and securely tighten
with a wrench.
4.
Connect the hose to the heater by rotating the hose fitting
clockwise.
5.
Securely tighten all gas connections with a wrench.
6.
Open the cylinder's gas valve and check all gas connections
with a soap and water solution. DO NOT USE A FLAME.
7.
Connect power cord to well-grounded 120V, 60 Hz, 1Ø
source of power.
8.
When using an extension cord, make certain that it is a 3-wire
(grounded) cord of proper wire size.
START
1.
Before heater ignition, always allow heater fan (blower) to run
for 20 seconds to purge fuel.
2.
Slowly open the main valve at propane cylinder.
3.
Rotate the valve control Knob to the LOW/IGN position then
depress the knob to release the fuel.
4.
After the heater lights, keep the valve control knob depressed
for 30 seconds then release and the heater will continue to
operate.
5.
Adjust burn rate by setting control knob to desired level.
6.
Igniter continues to fire as long as power cord is plugged in.
STOP
1.
Securely close valve on the propane cylinder.
2.
Continue to operate heater until all fuel in the hose has
burned, then turn control knob to OFF position.
3.
Once the unit has cooled, unplug the power cord.
RESTART AFTER SAFETY SHUTDOWN
1.
Securely close valve at propane cylinder. Unplug heater.
2.
Wait 5 minutes.
3.
Restart following "Start" procedure.
Mr. Heater, Inc.| Forced Air Propane Construction Heater
MAINTENANCE AND STORAGE
1.
The heater should be inspected before each use, and at least
annually by a qualified person.
2.
Before each use, check the soft "O" ring seal at the bullnose
of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number F273786.
3.
Turn off the gas at the LP-gas supply cylinder(s) when the
heater is not in use.
4.
When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the heater
and stored out of doors and in accordance with Chapter
5 of the standard for Storage and Handling of Liquefied
Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural
Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater is
working properly:
The flame is contained within the heater.
The flame is essentially blue with perhaps some yellow
tipping.
There is no strong disagreeable odor, eye burning or other
physical discomfort.
There is no smoke or soot internal or external to the heater.
There are no unplanned or unexplained shut downs of the
heater.
The parts lists and wiring diagram show the heater as it was
constructed. Do not use a heater which is different from that
shown. In this regard, use only the hose, regulator and cylinder
connection fitting (called a POL fitting) supplied with the heater.
IMPORTANT: Match the color stripe on the hang tag attached
to the hose assembly with the color on the label located near the
propane inlet fitting on the heater. Do not use alternates. For this
heater, the regulator must be set as shown in "specifications".
If there is any uncertainty about the regulator setting, have it
checked.
A heater which is not working right must be repaired, but only by
a trained, experienced service person.
In-warranty products will be repaired with no charge for either
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.
Out of warranty products will be repaired with a charge for parts
and labor.
HEATER ELEVATION ADJUSTMENT
This heater is equipped with an elevation adjustment panel
located at the exhaust end of the control box.
1.
Do not adjust the heater combustion tube elevation while
heater is running or hot. Adjustments to elevation should
only be made after the heater has cooled to touch.
2.
To adjust the heater combustion tube elevation, turn
the adjustment screw knob counterclockwise and lift the
combustion tube to desired position.
5
Operating Instructions and Owner's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhc125fav

Table of Contents