Advertisement

Active filter module
PUZ-A30/36/42NHA2
PUY-A30/36/42NHA2
L1, L2
Connect to
the DCL
(Reactor)
Upper side
+
Connect to
the outdoor
power circuit
board
(TABP1)
Connect to the outdoor power circuit board
(TABN1)
Connection and internal circuit diagram
PUZ-A30/36/42NHA2-BS
PUY-A30/36/42NHA2-BS
Connect to the outdoor power cir-
cuit board (CNAF)
1
: GND
2-1
: 15V DC
3-1
: Control signal
4, 5
: Not used
6-1
: Control signal
DCL
L1
L2
(+)
(–)
70
P
Connect to the outdoor power circuit board
(TABP2)
lo
Connect to the outdoor power circuit board
(TABN2)
ACTM
P
+
N1
N2
Io
N1
Non-connect
Lower side
N2
Non-connect