10-7. HOW TO CHECK THE COMPONENTS
<Thermistor feature chart>
Low temperature thermistors
• Thermistor <Outdoor pipe> (TH3)
• Thermistor <Outdoor 2-phase pipe> (TH6)
• Thermistor <Outdoor> (TH7)
Thermistor R0 = 15k' ± 3%
B constant = 3480 ± 2%
1
=15exp{3480( 273+t – 273 )}
t (:): R
t
=15exp{3480( 273+(T– 32)/1.8 – 273 )}
T (˚F): R
T
0:[32˚F]
15k'
10:[50˚F]
9.6k'
40:[104˚F]
20:[68˚F]
6.3k'
25:[77˚F]
5.2k'
Medium temperature thermistor
• Thermistor <Heatsink> (TH8)
Thermistor R50 = 17k' ± 2%
B constant = 4170 ± 3%
1
t (:): Rt =17exp{4170( 273+t – 323 )}
=17exp{4170( 273+(T– 32)/1.8 – 323 )}
T (˚F): R
T
0:[32˚F]
180k'
25:[77˚F]
50k'
50:[122˚F]
17k'
70:[158˚F]
8k'
90:[194˚F]
4k'
High temperature thermistor
• Thermistor <Discharge> (TH4)
Thermistor R120 = 7.465k' ± 2%
B constant = 4057 ± 2%
t (:): Rt =7.465exp{4057( 273+t – 393 )}
=7.465exp{4057( 273+(T– 32)/1.8 – 393 )}
T (˚F): R
T
20:[68˚F]
250k'
30:[86˚F]
160k'
40:[104˚F]
104k'
50:[122˚F]
70k'
60:[140˚F]
48k'
1
1
1
30:[86˚F]
4.3k'
3.0k'
1
1
1
1
1
1
1
70:[158˚F]
34k'
80:[176˚F]
24k'
90:[194˚F]
17.5k'
100:[212˚F]
13.0k'
110:[230˚F]
9.8k'
50
40
30
20
10
0
-20 -10 0 10 20 30 40 50
-4 -14 32 50 68 86 104122
200
150
100
50
0
25
77
500
400
300
200
100
0
25
77
57
:
°F
Temperature
:
50
75
100 110 125
°F
122
167 212 230 257
Temperature
:
50
75
100
120
°F
122
167
212
248
Temperature