Delta Heat DHPW22 Installation, Use & Care Manual page 5

Power burner
Table of Contents

Advertisement

GENERAL SAFETY REQUIREMENTS
The installation of this appliance must conform with local codes or, in the absence of local codes, either
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA
B149.1 or Propane Storage and Handling Code, B149.2
The utilization of an external electrical source requires that when installed, this outdoor cooking gas appli-
ance must be electrically grounded in accordance with the local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. Keep any
electrical supply cord, or the fuel supply hose away from any heated surfaces.
This outdoor cooking gas appliance shall be used only outdoors and shall not be used in a building, ga-
rage or any other enclosed area.
This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles and /or
boats.
Minimum clearance of 12 inches from the back and sides of the Power Burner to adjacent com-
bustible construction must be maintained. This outdoor cooking gas appliance shall not be locat-
ed under overhead-unprotected combustible construction.
Keep your Power Burner in an area clear and free from combustible materials, gasoline and other flam-
mable vapors and liquids.
DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the ventilation open-
ings of the cylinder enclosure free and clear from debris.
Check all gas connections for leaks with soapy water solution and brush. Never use an open flame.
(Reference page 6 for leak test procedure).
Check flexible hoses for cuts and wear that may affect the safety before each use.
Always use caution when operating the power burner in a windy area.
Never use the Power Burner without the drip pan installed and push all the way to the back of the Power
Burner. Without the drip pan, hot liquid and debris could leak downward and produce a fire hazard.
The pressure regulator supplied with the Delta Heat Gas Power Burner must be used. Replacement pres-
sure regulators must be those specified by Delta Heat.
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the State
of California to cause cancer and reproductive harm. To minimize exposure to the by-products of the
burning fuel or from combustion, always operate this unit according to the use and care manual and
provide good ventilation. California law requires businesses to warn customers of potential exposure
to such substances. For more information go to www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L'ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne reconnue
dans l'Etat de la Californie pour causer le cancer et des problemes de fertilite. Pour minimiser l'expo-
sition de ces-sous produits combustibles ou de la combustion, utiliser toujours cet appareil en con-
formitee au manuel d'utilisation et d'entretien en s'assurant egalement d'une bonne ventilation. La loi
de la Californie exige aux fabricants d'informer leurs clients aux risques d'exposition potentielle a de
telles substances. Pour plus d'information, visiter le site
In Massachusetts: All gas products must be installed using a "Massachusetts" licensed plumber or
gasfitter. A "T" handle type manual gas valve must be installed in the gas supply line to this appliance.
This applies to permanently installed natural gas and propane installations. This does not apply to
propane portable installations using a 20 pound tank.
www.P65Warnings.ca.gov

Advertisement

Table of Contents
loading

Table of Contents