Mitsubishi Electric MUZ-FH06NA Service Manual page 35

Outdoor unit
Table of Contents

Advertisement

No.
Symptom
LED indication
Outdoor unit
1-time fl ash
operates.
2.5 seconds OFF
16
3-time fl ash
2.5 seconds OFF
17
4-time fl ash
2.5 seconds OFF
18
MUZ-FH06/09/12
5-time fl ash
19
2.5 seconds OFF
Outdoor unit
7-time fl ash
operates.
2.5 seconds OFF
20
8-time fl ash
2.5 seconds OFF
21
9-time fl ash
2.5 seconds OFF
22
NOTE: 1. The location of LED is illustrated at the right fi gure. Refer to 10-6.1.
2. LED is lighted during normal operation.
The fl ashing frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the fl ashing frequency is "2".
ON
2.5-second OFF
OFF
OBH684C
Abnormal point/
Condition
Frequency drop by
FH06/09/12 When the input current exceeds approximately
current protection
FH15/18
Frequency drop by
Temperature of indoor coil thermistor exceeds 131 °F (55°C)
high pressure pro-
in HEAT mode, compressor frequency lowers.
tection
Frequency drop by
Indoor coil thermistor reads 46°F (8°C) or less in COOL mode,
defrosting in COOL
compressor frequency lowers.
mode
Frequency drop by
Temperature of discharge temperature thermistor exceeds
discharge tempera-
232°F (111°C), compressor frequency lowers.
ture protection
Outside temperature
When the outside temperature thermistor shorts or opens,
thermistor protec-
protective operation without that thermistor is performed.
tion
Low discharge tem-
Temperature of discharge temperature thermistor has been
perature protection
122°F (50°C) or less for 20 minutes.
The overcurrent fl ows into PFC (Power factor correction
MUZ-FH06/09/12
PAM protection
:IC820) or the DC voltage reaches 394 V or more, PAM stops
PAM: Pulse Ampli-
and restarts.
tude Modulation
Zero cross signal cannot be detected.
MUZ-FH15/18
Zero cross detecting
circuit
Inverter check mode The connector of compressor is disconnected, inverter check
mode starts.
0.5-second ON
2.5-second OFF
Condition
10A (FH06/09)/10.5A (FH12), compressor fre-
quency lowers.
Current from power outlet is nearing breaker ca-
pacity.
0.5-second ON
35
Remedy
The unit is normal, but check the
following.
• Check if indoor fi lters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air
circulation is short cycled.
• Check refrigerant circuit and refrig-
erant amount.
• Refer to 10-5.
"Check of LEV".
• Refer to 10-5.
"Check of outdoor
thermistors".
• Refer to 10-5.
Check of outdoor
thermistors.
• Refer to 10-5.
"Check of LEV".
• Check refrigerant circuit and refrig-
erant amount.
This is not malfunction. PAM pro-
tection will be activated in the fol-
lowing cases:
1 Instantaneous power voltage
drop. (Short time power failure)
2 When the power supply voltage
is high.
• It occurs with following cases.
1 Instantaneous power voltage
drop. (Short time power failure)
2 Distortion of primary voltage
• Refer to 10-5.
"Check of power
supply".
• Check if the connector of the com-
pressor is correctly connected.
Refer to 10-5.
"How to check
inverter/compressor".
Inverter P.C. board
MUZ-FH06/09/12
Flashing →
LED
MUZ-FH15/18
Flashing
LED