Starting the Engine
Before Starting the Engine
a. Inspect the generator and engine.
b. Disconnect all electrical loads from the generator.
c. Fill the engine with the proper amount and type of
both stabilizer-treated unleaded gasoline and oil.
Manual Start
1. Move the Economy (ESC) Switch to the OFF position.
2. Open the Fuel Valve on the back of the Generator under the Fuel Tank.
3. Pull the Choke out to the START position.
4. Turn the Engine Switch on.
5. Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline
to flow into the Engine's carburetor. Then pull the Starter Handle gently until resistance is felt.
Allow Cable to retract fully and then pull it quickly. Repeat until the Engine starts. Do not let the
Starter Handle snap back against the housing. Hold it as it recoils so it doesn't hit the housing.
If engine does not start:
• Check engine oil level.
Engine will not start with low or no engine oil.
• Check spark arrestor cleanliness.
Engine will not start if spark arrestor is clogged.
• For warm engine – push the Choke in to RUN position before trying to start it again.
6. The OUTPUT light illuminates when the Engine starts and the Generator produces power.
Allow the Engine to run for several seconds, then slowly push the Choke in.
Note: Moving the Choke too fast could stall the Engine.
IMpORTANT: Allow the Engine to run at no load for five minutes after each start-up so that the Engine can stabilize.
ITEM 57509
For technical questions, please call 1-888-866-5797.
2
CLOSE
3
4
OpEN