TC-14Z99M
2.9.

CRT Cut Off Adjustment

Preparation:
1. Connect the oscilloscope probe to TPL5.
2. Screen VR min.
3. Set the data Sub Bright, Bright.
4. In service Mode at "Bright" dac press [5] in factory mode to enter vertical line and adjust by volume down or up button.
5. Adjust "Screen VR" until 1-H Line appears.

2.10. Purity and Convergen Adjustment

1. Set the Brightness and Contrast controls to their maximum
positions.
2. Operate the TV set for 60 minutes.
3. Fully degausse the picture tube by using an external
degaussing coil.
4. Apply a crosshatch pattern signal and adjust the static
convergence magnets to the approximately correct position.
5. Receive a black and white signal.
6. Set the control as follows:
Red................minimum
Green.............minimum
Blue...............minimum
Press the Shipping button on the remote control twice to
select CRT Adjustment Mode to select low light.
7. Loosen the clamp screw for the Deflection Yoke A in Fig. 10
and move the Deflection Yoke as close to the purity magnet
as possible.
8. Adjust the purity magnetic rings so that a vertical green field
is obtained at the centre of the screen.
Before Colour Purity, Convergence and White Balance adjustment are attempted,
V. Height, H. Centre and Focus adjustments must be completed.
Colour Purity
9. Slowly push the Deflection Yoke and set it where a uniform
green field is obtained.
10. Re-adjust the Low Light controls to their correct settings
and make sure that a uniform white field is obtained.
11. Tighten the clamp screw A in Fig. 10.
10
Fig. 6
Fig. 21