Ebyte E78-470LN22S User Manual page 20

Asr6501 wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Test
command
Query
command
Setting
command
CSTAUS
( Query the
current status of
Parameter
the device )
Description
Return value
description
Example
Command
Command
character
Type
Test
command
Query
command
Setting
CJOIN
command
(Set Join)
Parameter
Description
Return value
description
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
AT+CSTAUS=?
AT+CSTATUS?
<status>:
00 – No data operation
01 – Data transmission
02 – Data transmission failed
03 – Data sent successfully
04 – JOIN succeeded (only in the first JOIN process)
05 – JOIN failed (only in the first JOIN process)
06 – The network may be abnormal (Link Check result)
07 – Successful data transmission, no
08 – Send data successfully, with
AT+CSTATUS?
+CSTATUS=03
OK
Query the current status of the device
Command Format
AT+CJOIN=?
AT+CJOIN?
AT+CJOIN=<ParaValue1>,
[ParaValue2],....
[ParaValue4]
<ParaTag1>, [ParaTag2], ......[ParaTag4]: Authentication parameter tag:
1, 2,......4 ;
[ParaValue1], [ParaValue2], ......[ParaValue4]: Authentication parameter
value: 1, 2,......4;
<ParaTag1>, indicates that the JOIN operation is performed, ,ParaTag1
Ranges:
0– stop JOIN
1– start JOIN,Restart the JOIN process again. For modules that enable hot
start, performing this action clears the saved JOIN context parameters.
E78-470LN22S User Manual
+CSTATUS:"status"
OK
+CSTATUS:<status>
OK
downstream
downstream
response
+CJOIN:<ParaTag1>,[ParaTag2],...[Para
Tag4
]
OK
+CJOIN:<ParaValue1>,[ParaValue2],...[
Para
Value4]
OK
If the input is legal, first return OK, then
start automatic authentication and return
the authentication result.
+CJOIN:OK Authentication succeeded
+CJOIN: FAIL authentication failed
19

Advertisement

Table of Contents
loading

Table of Contents