7.1.20 Time cutting function:
Connect the test program terminal on the mainboard after connecting the system to the power circuit. The
CPU of the main control will be 60 times faster.
7.2 Value of thermistor
R25 =10K
3%
B25 /50 =3700K 3%
Max.(K )
Temp.(( ))
-30
165.2170
-29
155.5754
-28
146.5609
-27
138.1285
-26
130.2371
-25
122.8484
-24
115.9272
-23
109.4410
-22
103.3598
-21
97.6556
-20
92.3028
-19
87.2775
-18
82.5577
-17
78.1230
-16
73.9543
-15
70.0342
-14
66.3463
-13
62.8755
-12
59.6076
-11
56.5296
-10
53.6294
-9
50.8956
-8
48.3178
-7
45.8860
-6
43.5912
-5
41.4249
-4
39.3792
-3
37.4465
-2
35.6202
-1
33.8936
0
32.2608
1
30.7162
Room sensor and Pipe Sensor
Normal(K )
Min.(K )
147.9497
132.3678
139.5600
125.0806
131.7022
118.2434
124.3392
111.8256
117.4366
105.7989
110.9627
100.1367
104.8882
94.8149
99.1858
89.8106
93.8305
85.1031
88.7989
80.6728
84.0695
76.5017
79.6222
72.5729
75.4384
68.8710
71.5010
65.3815
67.7939
62.0907
64.3023
58.9863
61.0123
56.0565
57.9110
53.2905
54.9866
50.6781
52.2278
48.2099
49.6244
45.8771
47.1666
43.6714
44.8454
41.5851
42.6525
39.6112
40.5800
37.7429
38.6207
35.9739
36.7676
34.2983
35.0144
32.7108
33.3552
31.2062
31.7844
29.7796
30.2968
28.4267
28.8875
27.1431
23
Functions and Control
Tolerance( )
-1.94
1.75
-1.93
1.74
-1.91
1.73
-1.89
1.71
-1.87
1.70
-1.85
1.69
-1.83
1.67
-1.81
1.66
-1.80
1.64
-1.78
1.63
-1.76
1.62
-1.74
1.60
-1.72
1.59
-1.70
1.57
-1.68
1.55
-1.66
1.54
-1.64
1.52
-1.62
1.51
-1.60
1.49
-1.58
1.47
-1.56
1.46
-1.54
1.44
-1.51
1.42
-1.49
1.40
-1.47
1.39
-1.45
1.37
-1.43
1.35
-1.41
1.33
-1.38
1.31
-1.36
1.29
-1.34
1.28
-1.32
1.26