  • Page 1 Pellet Stove series BURNIT AMBIENT V2 4G- 8 kW, 10 kW TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL FOR AUTHORIZED INSTALLER / SERVICE SHOP Version i0.1.2.
  • Page 2: Table Of Contents

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL CONTENT EXPLANATION OF SYMBOLS AND SAFETY INSTRUCTIONS ........3 1.1. Explanation of symbols ..................3 1.2. Requirements to stove installation room. ............3 1.2.1. Instructions for the installer. ................3 1.2.2. Instructions to installation user. ................4 1.2.3.Minimum clearances for installation and flammability of construction materials . 5 PRODUCT DESCRIPTION ..................5 FUELS ........................8 TRANSPOTATION OF THE STOVE ................8 DELIVERY OF THE STOVE ..................
  • Page 3: Explanation Of Symbols And Safety Instructions

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 1. EXPLANATION OF SYMBOLS is recommended. • Obligatory maintenance – the pellet AND SAFETY INSTRUCTIONS stove must be cleaned immediately 1.1. Explanation of symbols after each consumption of certified CAUTION! Important pellets between 800 kg to 1000 kg or...
  • Page 4: Instructions To Installation User

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Safety rules for user operation: DANGER of fire when burning - The pellet stove is designed to work flammable materials or liquids. - Flammable materials/liquids even in extreme weather. Still in case must not be left in close proximity of strong wind or very chill weather of the burner and heating boiler.
  • Page 5: Minimum Clearances For Installation And Flammability Of Construction Materials

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL refractory materials. For general safety considerations, we CAUTION! Hot surface! recommend that the boiler be placed on Burn hazard from touching a  system in operation. Stove casing a foundation made of class A material, see represents a dangerous hot table 2. surface while working. 2. PRODUCT DESCRIPTION 1.2.3. Minimum clearances installation...
  • Page 6: Fuels

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 3. FUELS Better control of fuel quantity. The small size of the pellets allows for precise fuel feeding. On the other hand, the supply of air for reaching optimal combustion efficiency is easier to adjust since the fuel quantity in the combustion chamber remains constant and predictable.
  • Page 7 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL This also provides for less frequent cleaning intervals for the burner. The table below contains the parameters which we recommend that you take into consideration when choosing fuel for your Pell burner. Table 3. European Certification of Wood Pellets for Heating Purposes Parameters Units ENplus-A1 ENplus-A2 EN-B 6 (± 1) 6 (± 1)
  • Page 8: Transpotation Of The Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 4. TRANSPOTATION OF THE STOVE following the instructions on the label - to be protected from adverse weather We recommend to transport the heating conditions (snow, rain and dust) from boiler to the installation site in its the shocks, and other activities likely to packaging placed on the pallet. During cause damage. In case of malfunction of transport and installation, depending on...
  • Page 9: Delivery Of The Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 5. DELIVERY OF THE STOVE - The area around and under the stove, must be made of stone, cement or other •Inspect the integrity of the packaging refractory material; upon delivery. mandatory install  •Unbox carefully. Check the pellet stove pellet stove on base of non - for visible defects or damages. Check the combustible materials.
  • Page 10: Installation Of The Heating Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Please entrust choosing a chimney and its 7. INSTALLATION OF THE HEATING installation by a qualified professional. STOVE The required distance between the boiler and the chimney is 300-600 mm. 7.1.Connecting the stove to a chimney Stove-to-chimney connection must...
  • Page 11: Type Of Tubes For Exhaust Gas System (Chimney)

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL The flue opening area should be at Data in the tables are for least 100 cm2. If the premises has an indicative purposes. air outflow/suction system installed, a Draught depends on the diameter, height, uneven sections along the relevant fresh air inflow must be provided...
  • Page 12: Connecting The Pellet Stove To The Mains Power Supply

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 7.4. Connecting the pellet stove to the mains power supply  Such connection must 7. Air Temp. Sensor performed by a technician / service shop authorized for such 12. Flue Gas Temp. Sensor operations. 14.Igniter Caution! ELECTRIC...
  • Page 13 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Scheme 2. Wiring diagram of connection of stove elements to the controller...
  • Page 14: Operation Of Pellet Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 5. TROUBLE-SHOOTING TABLE Cause Solution Ejection of unburned pellets into the combustion chamber of the stove Poor adjustment of the fuel-to-air Contact your installer. It is necessary to set the burner ratio from the burner controller properly using gas analyzer Utilization of low-quality pellets Use only fuel which meets the requirements specified in the...
  • Page 15: Requirements For The Cleaning And Maintenance Of Pellet Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 8.3. Requirements for the cleaning and 8.3.3. Cleaning and maintenance of the maintenance of Ambient V2 4G stove. pellet stove. Cleaning and maintenance of the pellet  stove must be performed regularly. IMPORTANT! Do not use acid- - Clean the stove outer surface, glass, rope containing...
  • Page 16 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 8.3.5. Cleaning the door glass Door glass is self-cleaned during stove operation. However, after several hours of operation, the glass may become dirty on the inside. The reason for this is the quality of the pellets and the operation of the exhaust system. The glass should be cleaned when the fire extinguished and cooled. Use a cotton cloth and a small amount of glass cleaning agent.
  • Page 17 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Cleaning the ash is through an opening above the burner. After cleaning, close the system. Scheme 7. Cleaning the ash from the damp tubes.
  • Page 18 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL...
  • Page 19: Microproccesor Controller

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 9. MICROPROCCESOR CONTROLLER 9.1. Explanation of Symbols.
  • Page 20: Controller Menus

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 9.2. Controller Menus.
  • Page 21 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL...
  • Page 22 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL...
  • Page 23 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL...
  • Page 24 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 7 Possible error codes Displayed on Problem Problem Code controller screen causes solution ---- Fill up the fuel bunker. “No fuel” icon Appears upon lack of fuel is on Restart controller from the ON/OFF key. А003 Check and clean the fire- “Cleaning” icon Firebox or flue are polluted and flashes...
  • Page 25 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 8 Controller settings Explanations M e a s u r e Values Parameter units code 8 kW 10 KW Maximum waiting time between charging and P 000 minutes fire build-up phase.
  • Page 26 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Explanations M e a s u r e Values Parameter units code 8 kW 10 KW P 030 Speed of the heat exchanger fan at shutdown. P 031 Speed of the heat exchanger fan at heat up. P 032 Speed of the heat exchanger fan at fuel ignition.
  • Page 27 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Explanations M e a s u r e Values Parameter units code 8 kW 10 KW Period between two self-cleaning during P 060 minutes combustion. Duration of the self-cleaning P 061 seconds during combustion.
  • Page 28: Technical Parameters Of Pellet Stove

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 10. TECHNICAL PARAMETERS OF PELLET STOVE AMBIENT V2 4G 10.1. Elements of pellet stove AMBIENT V2 4G Controller Heat resistant glass Cover of pellet hopper Pellet burner Door handle Power socket. Handle for cleaning the heat exchanger pipes Elements of pelllet stove AMBIENT V2 4G Schema 8.
  • Page 29: Technical Parameters Of Pellet Stove Ambient V2 4G

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 10.2. Technical parameters of pellet stove AMBIENT V2 4G Ambient V2 4G Ambient V2 4G 8 Plus 10 Plus Nominal Power 8 kW 10 kW Heat power /reduced power/ 5 kW 8 kW Height H Width L/ Depth D 460/500 460/500 Volume of water jacket V/Hz/W 220/50/120...
  • Page 30: Warranty Terms

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 11. WARRANTY TERMS 12. RECYCLINING AND DISPOSAL 11.1. Warranty Terms. Submit all packaging material for recycling The warranty terms are described in the according to the local regulations and Service booklet included in the supply requirements. At the end of life cycle of each product its components are due to be disposed of in 11.2. Aftersales service conformity with regulatory prescriptions. When you have bought a pellet stove Obsolete equipment shall be collected you must contact an authorized installer/ separately from other recyclable waste...
  • Page 31 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL...
  • Page 32 ISO 9001:2008 BUREAU VERITAS Certification tel.: +359 700 17 343 www.burnit.bg...