Installer / Service Manual BURNiT PM Comfort Plus Contents: Safety Precautions Technical characteristics 2.1. Delivery and unpacking of pellet stove 2.2. Description 2.3. Technical parameters Installation 3.1. General rules 3.2. Connecting of outer tube for fresh air flow 3.3. Exhaust gas system 3.4.
We rely on your professionalism and timely response. We are ready to assist you on each issue occurred. Our contact addresses per departments and divisions are available on our website: www.sunsystem.bg It is mandatory to assure a backup power generator of corresponding...
Page 4
Installer / Service Manual BURNiT PM Comfort Plus or objects because of wrong installation or misuse. 8. After removing the packaging material the end user must check up if all the parts/units are available and if something is missing he should notify the seller in order to receive the missing part.
Installer / Service Manual BURNiT PM Comfort Plus 2. Technical characteristics 2.1. Delivery and unpacking the pellet stove The pellet stove is delivered on wooden pallet, packed in carton box wrapped in foil and additionally secured with packing strap. Unpack carefully. Check the product for visible defects or damages. Check the door glass.
Installer / Service Manual BURNiT PM Comfort Plus Working pressure Average fuel consumption per hour h/kg Burn time of full pellet hopper at max.power CO content calculated to 13% O2 in the flue gas 0,02% 0,02% at nominal heat output Efficiency 87.5 91.2...
Installer / Service Manual BURNiT PM Comfort Plus The minimum distance from flammable materials must be 200 mm. In case the floor is made of flammable material (wood / parquet floor) it must be insulated with non- flammable one. The steel pipes for exhaust gases must be mounted at distance minimum 1.5 m. from any flammable materials.
Installer / Service Manual BURNiT PM Comfort Plus 3.3. Exhaust gas system The correct installed system for exhaust gases is of extreme importance. It is obligatory the installation to be performed by an authorized installer / service BURNiT ! Recommended parameters for installing the exhaust gas system: Model 13 kW 25 kW...
Installer / Service Manual BURNiT PM Comfort Plus 3.6. Diagrams for installing the exhaust gas system /connecting the pellet stove to chimney/ Diagrams are an example only. 10 –ЕN...
Installer / Service Manual BURNiT PM Comfort Plus 3.7. Roof installation of exhaust gas pipe The upper part of the pipe (chimney) is dеsigned for the proper outlet of the exhaust gases in the atmosphere. The tube must be protected from rain, snow and all objects, and to ensure discharging of exhaust gases in the atmosphere under windy conditions.
Installer / Service Manual BURNiT PM Comfort Plus • Weather the connection is correctly grounded. • The cable must not be with temperature higher than 75°C. • In case of direct connection to the power supply – contact an authorized electrician to perform the action.
Page 13
Installer / Service Manual BURNiT PM Comfort Plus Table: European Certification of Wood Pellets for Heating Purposes: Measures ENplus-A1 ENplus-A2 EN-B Parameters Diameter 6 (± 1) 6 (± 1) 6 (± 1) 8 (± 1) 8 (± 1) 8 (± 1) Length 15 ≤...
Installer / Service Manual BURNiT PM Comfort Plus The optimal density of the pellets which guarantees their quality is 605-700 kg per cubic meter. Pellet moisture content must not exceed 10%. Make sure you store your fuel in a dry and well-ventilated place.
Installer / Service Manual BURNiT PM Comfort Plus 6. Controller / Code PSYSQ 01000013/ 6.1. Description EasyTech.One is a Pellet stoves control system available in Air and Hydro version. Is characterised by: - Installing and use simplicity - Reliable and flexible functioning software. - Simple and direct user’s functions - Advanced functions available for the authorized installer to adapt to different stoves and installations...
Installer / Service Manual BURNiT PM Comfort Plus 6.3. Wiring controller Version 2 (V2) 17 –ЕN...
Page 18
Installer / Service Manual BURNiT PM Comfort Plus FUNCTION CHARACTERISTICS 230 Vac ± 10% 50/60 Hz Voltage Power Supply F1= Fuse T5,0 A Combustion Fan Triac Regulation 1A max Pump Triac Regulation 1A max Igniter Resistance Relè 3 A max Auger Pellet Engine Triac Regulation 1A max Contact ON/OFF Normally closed...
Installer / Service Manual BURNiT PM Comfort Plus 6.4. Control panel. Functions -1- LED / Display Blinking Stabilization phase Ignition Start phase Stove OFF Extinguishing phase Work phase Modulation/Standby phase Engine Auger ON Igniter Resistance ON Chrono Program enabled Pump ON Time Work Combustion Power set Combustion power change...
Page 20
Installer / Service Manual BURNiT PM Comfort Plus -3- Alarms DESCRIPTION Error Code Safety Thermostat HV1: signalled also in case of Block Stove OFF Safety PressureSwitch HV2: signalled with Block Combustion Fan ON Extinguishing Exhausting Temperature Block lowering Extinguishing for Exhausting over Temperature Block Encoder Error: No Encoder Signal (in case of Block...
Installer / Service Manual BURNiT PM Comfort Plus 6.5. User Menu (1) 6.5.1. Ignition / Extinguishing The Ignition and the Extinguishing are activated with a long pushing of the button The Ignition is signaled by the first blinking than fix led L1. The Work state is signaled by the fix led L4.
Page 22
Installer / Service Manual BURNiT PM Comfort Plus 6.5.4. Manual Pellet Loading The long pressure of button P2 activates the Pellet Manual Loading with activation of Auger engine in continuous way. The bottom display shows the actual function. The upper display shows the passed loading time.
Page 23
Installer / Service Manual BURNiT PM Comfort Plus 6.5.7. Display The activation is with a click of P1. tA = Room Temperature tF = Exhaust gas Temperature UF= Combustion Fan Speed [RPM/Volt]] HF02+ Product Code 6.5.8. Radio Remote Control Button 1 (blue) activates Extinguishing. Button 2 (red) activates Ignition.
Page 24
Installer / Service Manual BURNiT PM Comfort Plus On the Thermoregulator: Switch OFF the power supply (230 Vac) Switch ON the Power Supply pressing at the same time one button on the Remote Control waiting about 5 seconds until an acoustic signal is emitted confirming the code learned.
Page 25
Installer / Service Manual BURNiT PM Comfort Plus Push button P2 to enter. Use buttons P3/P4 to visualize the time bands B A ND D ISA B LED TIME SE T set: BA N D O FF Upper display visualizes: the TIME SET - - - - if the BAND is disabled D AY B A N D...
Installer / Service Manual BURNiT PM Comfort Plus 6.7. Installer’s Menu Push contemporary buttons P2+P4 and choose TPAr to enter in the TPAr installer menu, protected by password 6.7.1. Auger Menu TP O1 Setting of Auger TimeON defined for each phase/power in the Auger Period P05 If a value is set = 0 the Auger is disabled for the corresponding Power/Phase...
Page 27
Installer / Service Manual BURNiT PM Comfort Plus P25=1: Encoder version >values are in RPM; P25=0: No Encoder version >values are in VOLT. The set or calculated values are automatically delimited between in the thresholds P14 and P30. The fan of pellet stove has an integrated encoder. In this case, parameter P25 must be set as "1".
Page 28
Installer / Service Manual BURNiT PM Comfort Plus passage to P25=0 in case of no signal Encoder: alarm Er07 6.7.3. Thermostat`s Menu TP O4 13kW 25kW Code Description Probe Min. Max. Th01 Stove OFF Thermostat Exhausting [°C] Deactivation Igniter Th02 Exhausting [°C] Resistance Thermostat...
Page 29
Installer / Service Manual BURNiT PM Comfort Plus Hysteresis Increasing Delta Exhausting [°C] Temperature in Stabilization Delta Water Temperature in the boiler for Combustion Stove [°C] Power Automatic Regulation Increasing Delta Water Temperature over the Stove Thermostat to go from [°C] Modulation to Standby, if A13=2, at the end of T43...
Page 30
Installer / Service Manual BURNiT PM Comfort Plus Delay time Combustion Power Change Delay time Combustion Power Change in exit from Ignition Delay time for Standby Input Length signalling of fuel lack 3600 Work time of Pump 3600 Maximum time of inactivity of 9600 [ore] Pump...
Page 31
Installer / Service Manual BURNiT PM Comfort Plus Reached the Boiler Thermostat the stove goes in Modulation, then if d23 is satisfied and T43 is finished it goes in Standby Error Sensor Pressure disabled [nr] Error Sensor Pressure enabled Room Thermostat ON/OFF selected [nr] Room Probe selected The immediate Exit from StandBy is...
Installer / Service Manual BURNiT PM Comfort Plus 6.7.7. Extinguishing Thermostats Menu TP 13 Settings for each Combustion Phase/Power of the Exhausting Temperature under which, after the Pre-Extinguishing time T14, the stove goes in Extinguishing for no flame. These values occur with the Th03 Thermostat Code Description Probe...
Page 33
Installer / Service Manual BURNiT PM Comfort Plus If Exhausting → goes in Normal Temp. > Th09 6.8.5. Fixed Phase Combustion Timer Controls Auger Igniter If Exhausting → goes in Normal Temp > Th09 6.8.6. Variable Phase Combustion Timer Controls Auger Igniter If Exhausting...
Page 34
Installer / Service Manual BURNiT PM Comfort Plus Temp < Th06 from 6.6 Variable phase → goes in Extinguishing phase with error Er12 in case of finished number of attempts If Exhausting Control Temp > → goes in Normal after T06 Th06 +d01 6.8.8.
Page 35
Installer / Service Manual BURNiT PM Comfort Plus → Goes in Extinguishing with error Er03 If Exhausting Temp. > Th07 Thermostat If Water Temp.> Boiler Thermostat If Room → goes in Temperature > A01=1 Modulation Room Thermostat If Input AUX A07=1 open If Room...
Page 36
Installer / Service Manual BURNiT PM Comfort Plus after T14 If Exhausting waiting Temp. < Extinguishing Thermostat for the used power → Goes in Extinguishing with error Er03 If Exhausting Temp. > Th08 Thermostat → starts Timer If Water Temp.> Control Th25 after T15...
Page 37
Installer / Service Manual BURNiT PM Comfort Plus 6.8.12. Extinguishing Combustion Parameter Controls Auger Igniter Exhausting Temp. > → starts Timer T13 Th01 Extinguishing Thermostat Control after Exhausting Temp. > → Wait Th01 Thermostat Exhausting Final Cleaning Temp. < → starts Timer T16 Max Speed Th01 Thermostat...
Installer / Service Manual BURNiT PM Comfort Plus 6.9. Functions 6.9.1. Modem management The system manages a modem module (given on demand) for the dialogue with the stove through SMS to operate the Ignition, Extinguishing, State’s request and have information about the Block/Alarms conditions.
Page 39
Installer / Service Manual BURNiT PM Comfort Plus Start To start Ignition from stove OFF. The Modem sends back a message to the number from which it received the command with a status and a possible alarm error code Stop To start Extinguishing from stove ON.
Page 40
Installer / Service Manual BURNiT PM Comfort Plus 6.9.4. Brazier’s periodic cleaning When the stove is activated, the system automatically starts the brazier’s periodic clearing. With intervals as Timer T07 (minutes) the Combustion is taken to Periodic Cleaning Power according to parameters C08 and U08 for the Timer T08 (seconds). 6.9.5.
Page 41
Installer / Service Manual BURNiT PM Comfort Plus 6.9.7. Combustion fan correction management The user could correct the Combustion Fan Speed in Step – 7 ÷ 7 P16 is the percentage value of the single changing Step and is applied on the Work default values.
Page 42
Installer / Service Manual BURNiT PM Comfort Plus 6.9.9. Pressure Sensor Configuration 42 –ЕN...
Installer / Service Manual BURNiT PM Comfort Plus 6.9.10. Pressure Sensor Configuration Example: P26=0 Th18= 5 °C Th19= 50°C Th21= 80°C P26=1 Th18= 5 °C Th19= 40 °C Th21= 80 °C Th47= 8 °C 7. Cleaning and maintenance It's mandatory to clean regularly the pellet stove and the exhaust system. This ensures efficient stove operation.
Page 44
Installer / Service Manual BURNiT PM Comfort Plus ATTENTION! FOLLOW THESE STEPS WHEN CLEANING: • Switch OFF the pellet stove • Wait until the pellet stove cools completely. • Switch OFF the power supply. • Do not use flammable detergents. When making routine check the authorized service must do as following: •...
Page 45
Installer / Service Manual BURNiT PM Comfort Plus Removing the ash from the pellet stove Check the ash container at bottom part of pellet stove. Turn off the stove, wait until gets cool and then clean it. It`s mandatory to clean the ash container daily. Dispose the ashes in a non-combustible container with a lid.
Page 46
Installer / Service Manual BURNiT PM Comfort Plus 1) Dismount the cover of exhaust system. 2) Use a wire brush to clean the layered deposits 3) Model 25 kW : Clean the soot through the manholes on both sides of pellet stove. 3) Model 13kw –...
Installer / Service Manual BURNiT PM Comfort Plus Inspection and cleaning of exhaust gas system It`s mandatory to inspect the exhaust gas system at the beginning of each heating season. If the electric cable is damaged should be replaced with a new one. 8.