Pipe Insulation - Panasonic WH-ADC1216H6E5 Service Manual

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-ADC1216H6E5:
Table of Contents

Advertisement

Wire Stripping and Connecting Requirement
Wire stripping
No loose strand when insert

Pipe Insulation

1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
Indoor/outdoor
connecting terminal
board
5 mm or more
(gap between wires)
Conductor over
Conductor fully
insert
insert
ACCEPT
PROHIBITED
Conductor not
fully insert
PROHIBITED