Item
Power Source (Phase, Voltage, Cycle)
Input Power
Maximum Input Power For Heatpump System
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Starting Current
Running Current
Maximum Current For Heatpump System
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Power Cord
Thermostat
Protection Device
Item
Performance Test Condition
Outdoor Ambient
Operation Range
Water Outlet
Internal Pressure Differential
Noise Level
Height
Dimension
Width
Depth
Net Weight
Liquid
Refrigerant Pipe Diameter
Gas
Room
Water Pipe Diameter
Shower
Water Drain Hose Inner Diameter
Motor Type
Pump
No. of Speed
Input Power
Type
No. of Plates
Hot Water Coil
Size (H x W x L)
Water Flow Rate
Pressure Relief Valve Water Circuit
Type
Flow Switch
Set Point
Pressure Release Valve
(Ambient/Water)
(Ambient/Water)
Number of core
Length
°C (min. / max.)
°C (min. / max.)
(Ambient/Water)
Power Level dB
Unit
ø
V
Hz
Condition
A35W7
kW

Cooling: 3.56

kW
A
Condition
A35W7
A
Cooling: 16.0
A
%
m (ft)
Unit
Heating (Tank): - / 65*, Heating (Circuit): 25 / 55
kPa
Condition
A35W7
dB (A)
Cooling: 33
Cooling: 46
mm (inch)
mm (inch)
mm (inch)
kg (lbs)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
W
mm
3
l/min (m
/h)
kPa
l/min
kPa
12
Outdoor Unit
Single
230
50
A7W35

Heating: 2.53

5.30
1Ø / 24.0 / 5.30k
1Ø / 26.0 / 6.00k
— / — / —
16.0
A7W35
Heating: 11.5
24.0
Cooling: 97
Heating: 96
-
-
Electronic Control
Electronic Control
Indoor Unit
EN 14511
Cooling: 16 / 43

Heating: -20 / 35

Cooling: 5 / 20
Cooling: 38.0
Heating: 52.5
A7W35
Cooling: 33
Cooling: 46
717 (28-7/32)
598 (23-17/32)
1800 (70-27/32)
137 (302)
9.52 (3/8)
15.88 (5/8)
28 (1-3/32)
19 (3/4)
15 (19/32)
DC Motor
7 (Software Selection)
97
Brazed Plate
44
80 x 119 x 376
Cooling: 28.7 (1.7)
Heating: 34.4 (2.1)
Open: 300, Close: 265 and below
Magnetic Lead Switch
11.1
Open: 1150±200, Close: 700 and below
A2W35
Heating: 3.31
A2W35
Heating: 15.0
A2W35

Advertisement