Page 1
English English NEWTON NEWTON E-Smart E-Smart INSTRUCTION MANUAL INSTRUCTION MANUAL Newton 6 Newton 6 Newton 9 Newton 9 Newton 7 Newton 7 Newton 10 Newton 10 EVONIC - 104 INSTRUCTION MANUAL ISS. 6 EVONIC - 104 INSTRUCTION MANUAL ISS. 6...
CONTENTS EU Directives and UKCA Standards..............3 Important Information and Health & Safety............4 Components for Newton..................5 Installation......................6 Model Dimensions..................7 Installation Process..................9 Converting to GF / GF2 / GF3...............10 Installing the Side Panels / Converting to GF / GF2........11 Requirements and Checks................
EU DIRECTIVES All Evonic Fires products meet the requirements of the EC Directives. All Evonic Fires products meet the requirements of the EC Directives. These directives have been met by compliance with the following standards: These directives have been met by compliance with the following standards: EU 2011-65/EU 2015/863 Restriction of Hazardous Substances.
IMPORTANT INFORMATION AND HEALTH & SAFETY When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: • Read all of the instructions carefully before using the appliance, only use this appliance as described in this manual.
MODEL DIMENSIONS The model shown in these drawings is a Newton 10, however the same processes apply to all Newton models. Scan the QR code for more detailed specification drawings. EVONIC - 104 INSTRUCTION MANUAL ISS. 6 EVONIC - 104 INSTRUCTION MANUAL ISS. 6...
Page 8
MODEL DIMENSIONS Model Width Height Depth Overall unit Opening Overall unit With optional Open sides side panels Newton 6 686mm 671mm 665mm 458mm 197mm Newton 7 690mm 672mm 484mm 277mm 197mm Newton 9 876mm 868mm 700mm 495mm 197mm Newton 10...
INSTALLATION PROCESS Newton Model Newton Model (GF) (GF) (GF2) (GF2) (GF3) (GF3) Open Open 2 Open Sides 2 Open Sides 3 Open Sides 3 Open Sides Fronted Fronted Fit 2 Side Panels Fit 2 Side Panels Fit 1 Side Panel Fit 1 Side Panel Pages 11 Pages 11...
CONVERTING TO GF / GF2 / GF3 The appliance is shipped in the GF3 configuration, however all Newton models can be converted to be GF or GF2 with 2x side panels, these are an optional extra. GF Configuration A single opening at the front of the appliance. GF2 Configuration A single opening at the front and one open side.
INSTALLING THE SIDE PANELS / CONVERTING TO GF / GF2 Unscrew and remove the plaster kits from the side/s of the appliance. Screw in the side panel/s, on one or both sides. EVONIC - 104 INSTRUCTION MANUAL ISS. 6 EVONIC - 104 INSTRUCTION MANUAL ISS. 6...
INSTALLATION INSTALLATION REQUIREMENTS Before installing the appliance please read and take into account the following important requirements; • Consult a qualified professional to check the structure of the installation site. • The appliance must never be installed in front of an electrical socket. •...
Page 13
CHECKS BEFORE INSTALLATION We recommend turning on the appliance before installation, connect the appliance to a power source using the provided electrical lead, and depress the right side of the rocker switch. Once turned on and checked, remove the electrical lead from the wall and continue with the installation.
TOOLS REQUIRED • Tape Measure • Rear Wall Screws (Masonry type supplied) • Pencil • Top Mounted Bracket Screws x 6 (supplied) • Spirit Level • Top Mounted Bracket Wall Screws x 8 • Screwdriver (supplied) • PZ2 Screw Bit •...
Page 15
Determine the finished height and position that you want the appliance to be located. Then secure the wall bracket to the wall in the position you need using the wall plugs and screws provided. If you’re not securing the appliance to a masonry wall you will need to use the appropriate fixings.
Page 16
Screw the two top mounted brackets to the wall. You can now construct your stud wall/s around the appliance in the design of your choosing. When constructing the studwork, remember that the vents on the underside of the appliance need a minimum of 50mm clearance beneath them.
Page 17
Your plasterboard can now line up with the plaster kits on the edge of the appliance. Alternatively, the chrome side panels can be attached to the case with the magnets as shown below. Ensure that the magnets are positioned with the short side touching the case. EVONIC - 104 INSTRUCTION MANUAL ISS.
Page 21
Fan Re-setting & Replacement Scan the QR code to be taken to a video in our maintenance series. Please note; this video shows one of our glass fronted models, on Newton models there is no front glass, however the process is still the same.
Page 22
This warranty is in addition to and does not affect the purchasers statutory rights of consumers. REGISTER YOUR FIRE To register a product please visit: www.evonicfires.co.uk and complete the fields required under the Register a Product Section. By registering your appliance, an extra 12 months will be added to your warranty.