Proc_Cal_012: Aux 3 Dir A Valve Output Threshold; When To Perform; Calibration Order; Why Perform - Yale GC030VX Maintenance Manual

Calibration procedures
Table of Contents

Advertisement

Proc_Cal_012: Aux 3 Dir A Valve Output Threshold

Proc_Cal_012: Aux 3 Dir A Valve Output Threshold

WHEN TO PERFORM

Performed when troubleshooting procedures indicate,
when Aux 3 Dir A valve components have been serv-
iced, or when the Aux 3 Dir A valve is replaced.

CALIBRATION ORDER

1. Proc_Cal_025
2. Proc_Cal_001
3. Proc_Cal_002
4. Proc_Cal_012

WHY PERFORM

All electro-hydraulic valves have different operating
characteristics. One of the key characteristics is the
point at which hydraulic flow begins for a given com-
mand current. This cracking' current is determined by
this process.
A. TYPICAL DISPLAY WITHOUT KEY, WITH OPTIONS
B. TYPICAL DISPLAY WITH KEY, WITHOUT OPTIONS
Perform Proc_Cal_025: Hydraulic Valve Pressure Gage Installation, Proc_Cal_001: Service Password En-
try, and Proc_Cal_002: Hydraulic Valve Calibration Warm Up and Air Bleed before proceeding.
Information: "Creep" is defined as the threshold when a function first starts to move very slowly (barely percepti-
ble motion). The identification of this motion is defined as the "visual method." The method that provides more
consistent calibration is by monitoring the change in pressure when the function is activated; this is defined as
the "pressure method."
34
Table 14. Proc_Cal_012: Aux 3 Dir A Valve Output Threshold

HOW TO PERFORM

WARNING
Keep yourself and all others clear of the lift mech-
anism. Never allow anyone under or on the forks.
Never put hands, arms, head, or legs through the
mast or near the carriage or lift chains. This warn-
ing applies not only to the operator but also the
helper. A helper must not be near the load or the
lift mechanism while the operator is attempting to
handle a load. The lift mechanism has moving
parts with close clearances that can cause seri-
ous injury.
Refer to Table 14 for the procedures on how to per-
form Proc_Cal_012: Aux 3 Dir A Valve Output
Threshold.
Confidential/Proprietary - Do Not Copy or Duplicate
8000 YRM 1134

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents