DIRICKX AXIS DESIGN SYSTEM Technical Handbook

With axis and axor posts

Advertisement

Quick Links

AXIS
D
®
ESIGN
S
YSTEM
AXIS
AXOR
®
®
WITH
AND
POSTS
Technical Handbook
F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXIS DESIGN SYSTEM and is the answer not in the manual?

Questions and answers

Summary of Contents for DIRICKX AXIS DESIGN SYSTEM

  • Page 1 AXIS ® ESIGN YSTEM AXIS AXOR ® ® WITH POSTS Technical Handbook...
  • Page 2: Table Of Contents

    CONTENTS Description - Delivery AGES Recommendations for handling and storage Setting AXIS Design or AXOR posts to be sea- ® ® led in the ground or a low wall Description 1-2-1 Components delivered according to order 1-2-2 Setting AXIS Design or AXOR posts on base ®...
  • Page 3: Description Delivery

    Description Delivery 1-1 Recommendations for handling and storage - Keep the packing on the palette before use in order to avoid any damage to the product and any aes- thetic damage (to the coatings). - At least 2 people are needed for setting the fence. 1-2 Setting AXIS Design or AXOR posts to be concreted in the ground or a low wall...
  • Page 4: Setting Axis

    Description Delivery 1-3 Setting AXIS Design or AXOR posts on base plates fixed in the ground or on a low wall ® ® 1-3-1 D ESCRIPTION DIMENSIONS OF POSTS ON PLATES ® ® AXIS Panel AXOR Panel on base plate on base plate ®...
  • Page 5: Setting Axis

    Description Delivery 1-4 Setting AXIS Design posts on wall brackets ® TANDARD BRACKET ACADE BRACKET E : Distance between different brac- kets according to the nominal 1-4-1 D height of the fence (see page 21) ESCRIPTION ® Intermediate Post AXIS on a bracket Panel Standard...
  • Page 6: Ground Constraints

    Ground constraints MAKE A STUDY OF THE LIE OF THE LAND BEFORE SETTING: - if the terrain is sloping, allow for steps by offsetting each panel by 1 or 2 notches, or create lengthwise steps (where steps are made the posts must be more securely sealed). - in the corners, turn the posts to the required angle.
  • Page 7 Ground constraints OR FENCING NEAR A GATE OR AN ACCESS The backslide zone of tracked sliding and cantileve- This safe distance takes into account the exposed red sliding gates must be protected according to the parts of the human body according to the NF EN 294 NF EN 12635 standard (Gates equipping industrial standard (safety distances to avoid the upper mem- and commercial sites and garages - Installation and...
  • Page 8: Setting For Concreting

    Setting for concreting AXIS Design or AXOR posts ® ® in the ground or on a low wall 3-1 Preparation - Civil engineering Put the pegs in place Mark out the post (Ref. 1) every 100 m. centres. Stretch a line. Plumbline Dig holes of ø30 cm Mounting with posts...
  • Page 9 Setting for concreting AXIS Design or AXOR posts ® ® in the ground or on a low wall Set the first post Ram it down. (Ref. 2). Pour the concrete to +0.00 fill the hole. X = Sealing length (see page 20). Check the alignment If a kick board is to Overhang...
  • Page 10 Setting for concreting AXIS Design or AXOR posts ® ® in the ground or on a low wall If a kick board is to Attach the second be set: post (Ref. 6) onto the panel (Ref. 4). Fix the kick board (Ref.
  • Page 11 Setting for concreting AXIS Design or AXOR posts ® ® in the ground or on a low wall Repeat stages 8 to 18 to continue setting the fence. Clean the base of the post while moving forward, using a flexible brush and a little water. Remove the tensioning tools and the stays when the concrete has set (that is, after a minimum of 3 hrs).
  • Page 12: Installation On Base Plates

    Installation on base plates AXIS Design or AXOR posts ® ® at ground level or on a low wall 4-1 Preparation - Civil engineering 4-1-1 G ROUND MOUNTING Put the pegs in place Mark out the post (Ref. 1) every 100 m. centres.
  • Page 13: Installation

    Installation on base plates AXIS Design or AXOR posts ® ® at ground level or on a low wall 4-2 Installation Mark and drill the 3 Bolt down the first positions. INSIDE post (Ref. 2): the lug Ø 13 THE SITE must be on the side facing inside the site.
  • Page 14 Installation on base plates AXIS Design or AXOR posts ® ® at ground level or on a low wall Check the alignment Check the panel is of the post (Ref. 6). level (Ref. 4). Attach the second Spikes panel (Ref. 8) (spi- upwards downwards, crimps on the side facing the...
  • Page 15: Installation Using A Bracket

    Installation using a bracket AXIS Design posts on a wall ® 5-1 Preparation - Civil engineering NSURE THAT THE WIDTH OF THE WALL IS ADEQUATE FOR FIXING THE POSTS WITH BOLTS Ø12 MM ( HE PLATES ARE FIXED ON THE WALL WITH CONCRETE BOLTS CONTACT YOUR SUPPLIERS OF BOLTS SO AS TO DEFINE THE SPECIFICATIONS ACCORDING TO TERRAIN AND OR CONCRETE TYPE...
  • Page 16 Installation using a bracket AXIS Design posts on a wall ® tensioning Bolt down the post. tools position (Ref. 5). Check the alignment Check the panel is of the post (Ref. 6). level. Attach the second Spikes panel (Ref. 8) (spi- Repeat stages 5 to 11 to continue setting the upwards downwards, crimps...
  • Page 17: Maintenance Repairs

    Maintenance Repairs 6-1 Maintenance HECK THE CONDITION OF THE PANELS POSTS AND FITTINGS O NOT USE A HIGH PRESSURE CLEANER SOLVENTS OR OTHER CHEMICAL PRODUCTS WHICH COULD RISK DAMA GING THE COATING O NOT USE AN ABRASIVE SPONGE 6-2 Repairs If a post is damaged, it can be replaced by a repair post.
  • Page 18 Maintenance Repairs Pour 10 cm of conc- Put the two parts of rete into the bottom of the repair post (Ref. 9) the hole. into position (without screws or cover). Attach the adjacent Assemble the two panels (Ref. 4) in parts with the faste- the lugs of the two nings provided and...
  • Page 19 Maintenance Repairs 6-2-2 S AXIS ® ETTING THE ESIGN REPAIR POST WELDED ON A BASE PLATE panels Remove the dama- (Ref. 4) on either ged panels (Ref. 4) side of the damaged from the adjacent post (Ref. 2) along posts (Ref. 2). the vertical wire.
  • Page 20: After-Sales Service

    After-Sales Service Description Ref. Qty. Nominal Height Post Concreting RAL 6005* Concreting of Fence Length depth Long 1.00 m 40 cm PP600004 0.60 m Short 0.80 m 20 cm PP600003 Long 1.20 m 40 cm PP600005 0.80 m Short 1.00 m 20 cm PP600004 Long...
  • Page 21: Repair Post (Ref. 9)

    After-Sales Service Description Ref. Qty. Nominal Height Post Length RAL 6005* of fence Bracket centres 0.60 m 1.00 m PP600204 0.80 m 1.00 m PP600205 1.00 m 1.40 m PP600206 1.20 m 1.60 m PP600207 1.40 m 1.80 m PP600208 AXIS Design ®...
  • Page 22 After-Sales Service Description Ref. Qty. Nominal Height of Fence Post Length RAL 6005* 1.00 m 1.40 m PP400103 AXOR Post ® 1.20 m 1.60 m PP400104 for concreting 1.50 m 2.00 m PP400108 1.70 m 2.20 m PP400109 1.90 m 2.70 m PP400111 Nominal Height of Fence...
  • Page 23: Claims

    7-3 Guarantee - Products from the AXIS® Design and AXOR® range can be covered by the DIRICKX Professional 10 year gua- rantee. To request this, call or send a letter for the attention of your sales assistant, either on your own behalf or that of your customer.
  • Page 24 DIRICKX s.a.s. - 53800 CONGRIER - FRANCE Tél. 02 43 09 38 38 - Fax. 02 43 09 38 99 Edition 01 - 05 2003 http:// www.dirickx.fr - e-mail : commercial dirickx.com...