Siemens SIMATIC IPC Operating Manual page 13

Industrial edge device
Hide thumbs Also See for SIMATIC IPC:
Table of Contents

Advertisement

List of all LED status
The following table lists all LED status changes of the Edge Device during several processes:
Process
Description
Not connected
When the Edge Device is not connected to the IEM,
to the
the "Run" LED flashes green.
IEM
Connecting to
When the Edge Device is connecting to the IEM (after
the IEM
the USB flash drive is inserted), the "Run" LED flashes
green and the "Maintenance" LED flashes orange.
Connection to
When the Edge Device is connected successfully to the
the IEM
IEM, the "Run" LED lights up green.
was successful
Connection to
When the connection to the IEM has failed, the "Error"
the IEM
LED flashes red.
failed
IED-OS updates
When IED-OS updates are in progress, the
"Maintenance" LED flashes orange.
During the hard
When you initiate the hard reset, first the "Power" and
reset of
"Run" LEDs light up green. After that, the "Power" LED
lights up green and the "Run" LED flashes green. Then,
an Edge Device
all LEDs light up for a short time. Afterwards, the
"Power" LED flashes orange. Then, the "Power" LED
lights up green for a while. At the end, only the
"Power" LED lights up green and the "Run" LED flashes
green.
Hard reset was
When the "Power" LED lights up green and the "Run"
successful
LED flashes green, the hard reset was successful. The
Edge Device is not connected anymore to the IEM in
this case.
During the
When you initiate the system reset, first the "Power"
system reset
and "Run" LEDs light up green and after that, the
"Error" and "Maintenance" LED light up red
of an Edge
additionally. Then, the "Power" LED flashes orange.
Device
Afterwards, the "Power" LED lights up green and the
"Run" LED flashes green. At the end, only the "Power"
and "Run" LEDs light up green.
System reset
When the "Power" and "Run" LEDs light up green, the
was successful
system reset was successful. The Edge Device is still
connected to the IEM in this case.
Shutting down
After you have shutdown the Edge Device, the "Power"
the Edge
LED lights up orange.
Device
SIMATIC IPC Industrial Edge Device - Operation V1.3
Operating Manual, 09/2021, A5E51396302-AA
Power
Run
Error
Green
Green
Off
flashing
Green
Green
Off
flashing
Green
Green
Off
Green
Off
Red
flashing
Green
Off
Off
Orange
Off
Off
flashing
Green
Green
Off
flashing
Orange
Off
Off
flashing
Green
Green
Off
Orange
Off
Off
LED Status
Maintena
nce
Off
Orange
flashing
Off
Off
Orange
flashing
Off
Off
Off
Off
Off
13

Advertisement

Table of Contents
loading