Download Print this page
Delta BX6.3_AC100 Quick Installation Manual
Delta BX6.3_AC100 Quick Installation Manual

Delta BX6.3_AC100 Quick Installation Manual

Battery storage system

Advertisement

Quick Links

BX6.3_AC100 user manual
For more instruction and specification, please scan QR-code to see user manual.
> Battery > BX6.3_AC100 Operation and Installation Manual
https://mydeltasolar.deltaww.com/?p=product_manual
Descriptions of Components
Object
Qty
Description
Delta BX6.3_AC100
1
1
Residential AC ESS
The Instruction to provide the information of safety,
2
Quick Installation Guide
1
Installation and specification.
3
WiFi antenna
1
2.4 Ghz Wi-Fi Antenna (IPX7)
4
Antenna Bracket
1
To support Wi-Fi antenna on BX6.3_AC100
5
Rubber cover
1
Protective cover for non-critical waterproof and dust prevent
6
Plastic cover
3
Protective cover for non-critical waterproof and dust prevent
7
AC Plug
1
Connector for AC connection
8
Wiring Cover
2
Protective cover to prevent users from touching the power cable
9
Current sensor
1
120A current transformer
10
CT cable
1
Cable for CT connection
11
H4 Wrench
2
To disconnect H4 connector
Dimensions and Interface Overview
unit: mm
BT-
BT+
Push
Battery
Button
Earth
Ex Comm.
* Wi-Fi reset button function
Operation
Wi-Fi LED Status
Wi-Fi LED flashing once
Push 3s~10s
every half a second
Push 10s~20s
No flash
Wi-Fi LED flashing once
Push 20s~
every one seconds
5013285903
Quick Installation Guide
Battery Storage System
BX6.3_AC100
570
250
It is prohibited to open the front door.
It may cause failure and the warranty
will void once the door is opened.
Wi-Fi Reset *
AC Output
COMM.
RS-485 / DRM /
Dry contact / CT port
Explanation
Reset Wi-Fi module
No function
Reset Wi-Fi module, and Wi-Fi password
returns to the default: DELTASOL
Do not open this product or insert tools due to shock and fire hazard which may cause injury.
When installing this product you must adhere to the following instructions:
● The product is intended to be installed and operated by qualified personnel or service personnel only.
● Do not power up the device before installation is complete.
● All circuit breakers must be in the OFF position before commencing installation.
● Do not install BX6.3_AC100 near or on flammable surfaces.
● Please mount BX6.3_AC100 tightly on a solid / smooth surface.
● Install BX6.3_AC100 in a location that prevents damage from flooding.
● Do not expose BX6.3_AC100 to ambient temperatures above 60°C or below -20°C.
● Operating or storing BX6.3_AC100 in temperatures outside its specified range might cause damage
to BX6.3_AC100.
Danger to life through electric shock
Potentially fatal voltage is applied to the unit during operation.
This voltage persists even 60 seconds after disconnection of the power supply.
Never open the unit.
The unit contains no components that must be maintained or repaired by the operatoror installer.
Opening the housing will void the warranty.
60 seconds
LED Indicators
LED
Grid
SPS
(Stand-alone Power System)
Comm.
Grid / SPS
Push Button
Status
BX6.3_AC100 power OFF
BX6.3_AC100 power OFF
BX6.3_AC100 power ON already
Installation
100 mm
100 mm
* Please refer to regulation AS/NZS 5139:2019 for detail installation space requirement.
To avoid extra fireproof cement sheeting installation requirement, it is recommended to keep at least 300mm
between the wall and BX.
Please keep enough space
for wiring and pipping.
(Max.: 400 mm)
Warning
Comm.
LED Status
Definition
GREEN ON
On Grid mode
GREEN FLASH 1s ON/OFF
On Grid count down
GREEN FLASH 0.1s ON/OFF
Grid setting "default"
RED ON
PCS Error
GREEN ON
Standalone mode
GREEN FLASH
Standalone count down
RED ON
Battery Error
RED FLASH
Battery Power OFF
GREEN ON
Communicating
OFF
No communication
GREEN FLASH
SBMS Balance mode
Grid ON 1s
SPS ON 1s
SBMS Force_CHG
Maintenance Mode
Operation
Action
Power ON the unit
Grid supplied
(AC start-up)
Power button push > 20 sec
Power ON the unit
(until grid green LED flash)
(Cold start-up)
Power button push >1 sec
Power OFF the unit
>30 mm*
100 mm
100 mm
90°
500 mm
Grid
SPS

Advertisement

loading

Summary of Contents for Delta BX6.3_AC100

  • Page 1 ● Install BX6.3_AC100 in a location that prevents damage from flooding. Descriptions of Components ● Do not expose BX6.3_AC100 to ambient temperatures above 60°C or below -20°C. ● Operating or storing BX6.3_AC100 in temperatures outside its specified range might cause damage to BX6.3_AC100. Danger to life through electric shock Potentially fatal voltage is applied to the unit during operation.
  • Page 2 3000 VA 4500 VA According to country setting Voltage (Programmable 230Vac ± 20%) * Please do not remove all the rubber covers on BX6.3_AC100 if BX6.3_EX100 On Grid Nominal current 13 A 19.6 A is not installed. Stand-Alone Nominal current 13 A 19.6 A...

This manual is also suitable for:

Bx12.6_ac100