Wiring Diagrams - Amana GMES80 Service Instructions Manual

80% single stage gas furnaces
Table of Contents

Advertisement

WIRING DIAGRAMS

E36
STEADY ON
0
OFF
1 FLASH
1
2 FLASHES
2
3 FLASHES
3
4 FLASHES
4
5 FLASHES
5
6 FLASHES
6
7 FLASHES
7
RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND
C
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GR GREEN
BK BLACK
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
= NORMAL OPERATION
= CONTROL FAILURE
= SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
= PRESSURE SWITCH STUCK CLOSED
= PRESSURE SWITCH STUCK OPEN
= OPEN HIGH LIMIT
= FLAME SENSE WITHOUT GAS VALVE
= OPEN ROLLOUT
= LOW FLAME SIGNAL
NOTES:
PK PINK
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
BR BROWN
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
WH WHITE
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
BL BLUE
RATING OF AT LEAST 105 
GY GRAY
4. BLOWER SPEEDS MUST BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION
RD RED
REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE
CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
(
PcBBF145 c
witH
C
G
TO
Y
MICRO
W
R
XFMR (3)
XFMR-H
FP (2)
IGN
IND
LINE-H
DOOR
SWITCH
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
TO 115VAC/
OVERCURRENT PROTECTION DEVICE
POWER SUPPLY WITH OVERCURRENT
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
C. USE COPPER CONDUCTORS ONLY.
*mEs80/*cEs80
ontrol
INTEGRATED
HUMIDIFIER
CONTROL MODULE
XFMR (6)
GND (8)
GAS
C2
MVC (9)
VALVE
M1
MV (12)
ID BLOWER
PRESSURE
AUXILIARY
SWITCH
LIMIT CONTROLS
NO
PS (10)
C
PSO (4)
HLI (7)
HLO (1)
AUTO RESET
PRIMARY
RO2 (11)
LIMIT
CONTROL
RO1 (5)
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON SOME MODELS)
24 VAC
40 VA
TRANSFORMER
XFMR-N
115 VAC
FLAME SENSOR
HOT SURFACE
IGNITER
IGN-N
ID
BLWR
IND-N
COOL-H
CIRCULATOR
BLWR
CIR-N
HEAT-H
LINE-N
JUNCTION BOX
DISCONNECT
L
GND
N
1Ø /60 HZ POWER SUPPLY WITH
LINE-N
LINE H
TO 115 VAC/ 1/60HZ
PROTECTION DEVICE
EQUIPMENT GND
FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
0140F02448-A
B
)
oard
57