1. Setting Up

The following standard checks should be made prior to starting your machine:
Check your fuel supply, the fuel tank holds 50 gallons, a full tank should last all day.
Check engine oil level. If oil is needed, add a good grade of H.D. oil. See engine manual
for grade based on operating conditions.
Check water level in engine radiator. Add as necessary. If in cold climates, a periodic
check should be made on anti-freeze effectiveness.
There are four alemites on the mixer, two on each end. These should be greased as
described in "The Strong-Mate Mixer" section, and at the end of each day's operation.
Check inside the mixer and hopper for foreign items.
Lower leg stand on the machine. Set-up machine with the rear of the machine slightly
lower than the front. The legs should be set on 2" x 6" lumber to prevent the legs from
sinking into the ground. The machine weight should be distributed evenly on all four
legs.
Stretch out water hose and attach to water supply. Before starting engine, make sure that
transmission is in neutral. In order to start the engine, use the following procedure:
o Pull engine throttle about 1/3 of the way out.
o Turn ignition key to ON position...indicated by generator light coming on.
o Hold down inter-lock button and engage started button simultaneously.
o Choke if necessary.
o Continue holding inter-lock button down for about 5 seconds after engine has
started or until safety gauges have time to stabilize.
o Allow engine to warm at idle speed – 800-1200 RPM.
Operation Procedure