Volumetric IR Process Gas Monitor
PIRVOL Series
4.1
7/07
95-8522

Advertisement

Table of Contents
loading

Summary of Contents for UTC Fire and Security DET-TRONICS 95-8522

  • Page 1 Instructions 95-8522 Volumetric IR Process Gas Monitor PIRVOL Series 7/07 95-8522...
  • Page 2: Table Of Contents

    Table Of Contents application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features.
  • Page 3: Application

    INSTRUCTIONS Volumetric IR Process Gas Monitor PIRVOL Series APPLICATION PIRVOL Infrared Process Gas Monitors provide continuous measurement of hydrocarbon vapors in the range of 0 to 90% by volume. The PIRVOL-LT model provides an analog 4 to 20 milliampere signal output that is proportional to methane vapor concentrations from 0 to 90% by volume, while the PIRVOL-VR model provides an analog 4 to 20 milliampere signal that is...
  • Page 4 PIRVOL-LT CROSS SENSITIVITy— Table 1—Current Loop Output Levels and Corresponding Status Indications PIRVOL-LT provides a linear analog 4 to 20 mA signal output in response to methane vapor concentration Current Level Status of 0 to 90% by volume. The presence of other 23.0 ma 100% by volume hydrocarbon vapors in the sample stream will cause...
  • Page 5 RFI/EMI PROTECTION— Cross Sensitivity of PIRVOL-LT to Propylene EN50081-1. Class B, EN50082-1 (IEC 801-2, 3, 4). Operates properly with 5 watt walkie talkie keyed at 1 Propylene meter. % Gas Reading ENCLOSURE MATERIALS— >120 Copper-free aluminum (clear anodized) enclosure. >120 Stainless Steel (316 electropolished) enclosure.
  • Page 6: Description

    JUNCTION BOX TERMINALS— DESCRIPTION PIRVOL junction box terminals UL/CSA rated for 14 to 22 AWG wire; terminals DIN/VDE rated for 2.5 mm2 DETECTION METhOD wire. PIRVOL operates on the infrared absorption CERTIFICATION— principle. A beam of modulated light is projected CSA: Class I, Division 1, Groups B, C and D;...
  • Page 7: Signal.display.device

    SIGNaL DISPLay DEVICE OPERaTING MODES If a local or remote digital display for indication Warmup of detected gas concentration is required, it is recommended to utilize a scalable display device When power is applied to the PIRVOL, it enters a with a clearly marked unit of measurement in % by Warmup mode (for approximately one minute) in which volume.
  • Page 8: Installation

    Normal INSTALLATION In the normal operating mode, the 4 to 20 milliampere signal level corresponds to the detected gas DEVICE MOUNTING ORIENTaTION concentration. The PIRVOL continuously checks It is highly recommended that the PIRVOL be installed for system faults or initiation of calibration, and in the horizontal position.
  • Page 9: Wiring.procedure

    Figure 7—Short PIRVOL Junction Box 24 VDC Figure 6—Tall PIRVOL Junction Box with Window POWER SUPPLy – WIRING PROCEDURE – IMPORTANT Do not apply power until the wiring procedure is PIRVOL 4 TO 20 MILLIaMPERES complete and has been verified. CaLIBRaTE BLaCK WhITE...
  • Page 10: Detector.separation.(Optional)

    CaLIBRaTE SWITCh JUNCTION hOLD CaLIBRaTION MaGNET aT OUTSIDE BaSE OF JUNCTION REMOTE LED BOx aT ThIS LOCaTION PIRVOL TO aCTIVaTE CaLIBRaTION SWITCh DETECTOR SUITABLE WIRING. MUST MEET ALL LOCAL CODES. CONTROL DEVICE, SUCH AS TRANSMITTER B2030 Figure 11—Detector Separation Mounting and Connecting Procedure for Detector Separation The PIRVOL junction box can be mounted to a wall B2056...
  • Page 11: Startup.procedure

    STARTUP PROCEDURE TROUBLESHOOTING NOTE Refer to Table 2 to isolate and correct malfunctions with the PIRVOL. Caution should be exercised when applying this and any electronic device to explosive vapor extraction and measurement applications. MAINTENANCE Typical hazards in these applications include small fitting vapor leaks, resulting in dangerous gas concentrations near or within the system It is recommended to have spare IR Modules on hand...
  • Page 12: Disassembly.and.cleaning.procedure

    DISaSSEMBLy aND CLEaNING PROCEDURE 1. Remove the sample draw cup from the front of the PIRVOL. See Figure 12. The PIRVOL should be inspected periodically to ensure that its performance is not impaired by fouled 2. Perform a visual inspection of the sample draw optics or by clogging of the sample draw cup or cup and associated plumbing, and clean as hydrophobic screen.
  • Page 13: Calibration

    ELECTRONICS ASSEMBLY SAMPLE DRAW CUP WINDOWS UL APPROVED O-RINGS MIRROR ASSEMBLY HYDROPHOBIC SCREEN MIRRORS (2) B2032 Figure 12—PIRVOL Disassembly for Cleaning CaLIBRaTION Calibration Procedure In the event the PIRVOL optics are fouled and To perform a zero calibration of the PIRVOL, follow the complete dis-assembly is required for cleaning, a sequence described in Table 3.
  • Page 14: Device.repair.and.return

    Table 3—Calibration Sequence Description Current Operator action Normal operation/no gas present 4.0 ma If the possibility of background gases exists, purge the sensor with clean air to ensure accurate calibration. Initiate calibration 2.2 ma On steady Initiate the calibration sequence by holding the calibration magnet against the side of the junction box or activating the external calibrate pushbutton for one second.
  • Page 15: Ordering.information

    ORDERING INFORMATION SPaRE PaRTS Part Number Description PIRVOL DETECTORS 007128-001 Sample Draw Cup with O-Rings Refer to the PIRVOL OS Matrix. and Fittings 007128-002 O-Ring Kit (UL) 006297-003 Hydrophobic Screen IR MODULE ONLy 006680-001 Silicone Grease (Without cup, for field replacement only) Part Number Description aSSISTaNCE...
  • Page 16 Detector Electronics Corporation 6901 West 110th Street Minneapolis, MN 55438 USA T: 952.941.5665 or 800.765.3473 F: 952.829.8750 W: http://www.det-tronics.com ® ® X3301 Multispectrum PointWatch Eclipse Eagle Quantum Premier Eagle Logic Solver E: detronics@detronics.com IR Flame Detector IR Combustible Gas Detector Safety System Safety System Det-Tronics, the DET-TRONICS logo, Eagle Quantum Premier, and Eclipse are registered trademarks or trademarks of Detector Electronics...