12.2.4.1
Wire Stripping, Connecting Requirement
Wire stripping
No loose strand
when inserted
RISK OF FIRE
JOINING
OF WIRES
MAY CAUSE
WARNING
OVERHEATING
AND FIRE.
Do not joint wires.
OR
12.2.4.2
Cutting and flaring the piping
1
Please cut using pipe cutter and then remove the burrs.
2
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
down to avoid the metal powder entering the pipe.
3
Please make flare after inserting the flare nut onto the copper pipes.
Pipe
Reamer
Point down
1. To cut
2. To remove burrs
Indoor/outdoor
connection
terminal board
5 mm
or more
(gap between wires)
OR
Handle
Bar
Yoke
Core
Red arrow mark
Clamp handle
3. To flare
Conductor
fully inserted
ACCEPT
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to
national wiring rules.
0 – 0.5 mm
Improper flaring
Bar
Inclined Surface
Copper
damaged
pipe
29
Conductor
over inserted
PROHIBITED
OR
When properly flared, the internal
surface of the flare will evenly shine
and be of even thickness. Since the
flare part comes into contact with the
Cracked Uneven
connections, carefully check the flare
thickness
finish.
Conductor not
fully inserted
PROHIBITED